Observational Study
. 2020 Jan 27;13(2):170-179.
doi: 10.1016/j.jcin.2019.08.035.

Three Generations of Self-Expanding Transcatheter Aortic Valves: A Report From the STS/ACC TVT Registry

Affiliations
Free article
Observational Study

Three Generations of Self-Expanding Transcatheter Aortic Valves: A Report From the STS/ACC TVT Registry

John K Forrest et al. JACC Cardiovasc Interv. .
Free article

Abstract

Objectives: The aim of this study was to assess the evolution of early outcomes for 3 iterative self-expanding transcatheter aortic valves.

Background: Over the past decade there have been rapid advancements in transcatheter aortic valve replacement (TAVR) technologies, including 3 generations of supra-annular self-expanding transcatheter systems.

Methods: Data from the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry for patients undergoing TAVR with CoreValve, Evolut R, or Evolut PRO valves to treat tricuspid aortic stenosis between January 2014 and September 2017 were obtained. Patient risk and echocardiographic data are site reported. Valves analyzed included 23-, 26-, and 29-mm sizes to fit 18- to 26-mm annular diameters. Propensity score matching was performed using the Evolut PRO group as the common reference.

Results: Of 18,874 patients undergoing TAVR at 381 centers, 5,514 patients were implanted with CoreValve, 11,295 with Evolut R, and 2,065 with Evolut PRO valves. At 30 days, there were significantly fewer patients with more than mild aortic regurgitation for the unmatched (7.8% CoreValve, 5.2% Evolut R, and 2.8% Evolut PRO; p < 0.001) and matched populations (8.3% CoreValve, 5.4% Evolut R, and 3.4% Evolut PRO; p = 0.032). The mean aortic valve gradients at 30 days in the matched populations were <8 mm Hg for all 3 valves (7.3 mm Hg CoreValve, 7.5 mm Hg Evolut R, 7.2 mm Hg Evolut PRO).

Conclusions: Advancements in transcatheter valve technologies and expanding indications for TAVR have resulted in improved outcomes for patients undergoing TAVR in the United States with self-expanding, supra-annular valves. In particular, the addition of an outer pericardial tissue wrap designed to enhance sealing at the level of the aortic annulus has resulted in very low rates of significant aortic regurgitation while maintaining excellent hemodynamic status.

Keywords: aortic stenosis; paravalvular leak; self-expanding; transcatheter aortic valve replacement.