Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Mar 1:1100:118-130.
doi: 10.1016/j.aca.2019.12.006. Epub 2019 Dec 3.

An immuno-MALDI mass spectrometry assay for the oral cancer biomarker, matrix metalloproteinase-1, in dried saliva spot samples

Affiliations

An immuno-MALDI mass spectrometry assay for the oral cancer biomarker, matrix metalloproteinase-1, in dried saliva spot samples

Yung-Chin Hsiao et al. Anal Chim Acta. .

Abstract

Oral cavity cancer is a common cancer type that presents an increasingly serious global problem. Oral squamous cell carcinoma (OSCC) accounts for >90% oral cancer cases. No biomarker tests are currently available for management of this cancer type in clinical practice. Previously, we validated matrix metalloproteinase-1 (MMP1) as one of the most promising salivary biomarkers for OSCC detection. Development of a convenient, rapid and high-throughput assay should further facilitate application of salivary MMP1 measurement for early detection of OSCC. The present study aimed to develop a workflow comprising dry saliva spot (DSS) sampling and immunoenrichment-coupled MALDI-TOF MS (immuno-MALDI) analysis to quantify salivary MMP1. We generated recombinant MMP1 protein and anti-peptide antibodies against MMP1, which were used to optimize the procedures of the entire workflow, including DSS sampling, on-paper protein digestion and elution, KingFisher magnetic particle processor-assisted immuno-enrichment and MALDI-TOF MS analysis. The established workflow was applied to measure salivary MMP1 levels in DSS samples from 5 healthy donors and 9 OSCC cases. The newly developed workflow showed good precision (intra-day and inter-day variations <10%) and accuracy (80-100%) in quantification of MMP1 in DSS samples, with the limit of quantification at 3.07 ng/ml. Using this assay, we successfully detected elevated salivary MMP1 levels (ranging from 5.95 to 242.52 ng/ml) in 7 of 9 OSCC cases while MMP1 was not detectable in samples from the 5 healthy donors. In comparison, the traditional immunoassay was not effective in measuring MMP1 in DSS samples, highlighting the significant advantage of our immuno-MALDI assay. The DSS sampling format confers high flexibility and convenience of collection, storage and delivery of saliva specimens and the KingFisher-assisted immuno-MALDI analysis renders the assay as suitable for high-throughput screening. By combining the two features, the workflow developed in this study should facilitate improvement of molecular diagnostic tests for OSCC using salivary MMP1 as a biomarker.

Keywords: Biomarker; Dried saliva spot; Immuno-MALDI; Metalloproteinase-1; Oral cancer.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

MeSH terms

LinkOut - more resources