Factors associated with diagnostic accuracy, technical success and adverse events of endoscopic ultrasound-guided fine-needle biopsy: A systematic review and meta-analysis
- PMID: 32003100
- DOI: 10.1111/jgh.14999
Factors associated with diagnostic accuracy, technical success and adverse events of endoscopic ultrasound-guided fine-needle biopsy: A systematic review and meta-analysis
Abstract
Background and aim: Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is used to diagnose lesions within or adjacent to the digestive tract. However, there is no report on the overall diagnostic accuracy, technical success, and adverse events of FNB. The aims of this study were to conduct a systematic review and meta-analysis to comprehensively assess the diagnostic accuracy, technical success, and adverse events of FNB.
Methods: Pubmed, Embase, and Cochrane Library databases were searched for relevant articles published in English from January 1998 to May 2019 (No. CRD42019141647). Primary outcomes were EUS-FNB related diagnostic accuracy rate, technical success rate, and adverse event rate.
Results: A total of 51 articles including 5330 patients met our criteria. The overall EUS-FNB related diagnostic accuracy rate, technical success rate, and adverse event rate was 90.82% [95% confidence interval (CI) 88.69-92.76%], 99.71% [95% CI 99.35-99.93%], and 0.59% [95% CI 0.29-1.0%], respectively. Biopsy with 22G needle could increase the diagnostic accuracy rate and technical success rate to 92.17% [95% CI 89.32-94.61%] and 99.88% [95% CI 99.64-99.99%], respectively, and decrease the adverse event to 0.37% [95% CI 0.08-0.87%]. Moreover, it showed that 22G needle was an independent factor associated with a higher diagnostic accuracy rate and technical success rate and a lower adverse event rate (P = 0.04, P < 0.001, and P = 0.04, respectively) by univariate and multivariate meta-regression analyses.
Conclusion: Endoscopic ultrasound-guided fine-needle biopsy is a feasible and safe procedure for lesions within or adjacent to the digestive tract. Biopsy using 22G needle could increase the diagnostic accuracy rate and technical success rate and decrease adverse event rate during the FNB procedure.
Keywords: FNB; adverse event rate; diagnostic accuracy rate; technical success rate.
© 2020 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
References
-
- Ribeiro A, Vazquez-Sequeiros E, Wiersema LM, Wang KK, Clain JE, Wiersema MJ. EUS-guided fine-needle aspiration combined with flow cytometry and immunocytochemistry in the diagnosis of lymphoma. Gastrointest. Endosc. 2001; 53: 485-491.
-
- Mesa H, Stelow EB, Stanley MW, Mallery S, Lai R, Bardales RH. Diagnosis of nonprimary pancreatic neoplasms by endoscopic ultrasound-guided fine-needle aspiration. Diagn. Cytopathol. 2004; 31: 313-318.
-
- Iglesias-Garcia J, Poley JW, Larghi A et al. Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study. Gastrointest. Endosc. 2011; 73: 1189-1196.
-
- Larghi A, Iglesias-Garcia J, Poley JW et al. Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study. Surg. Endosc. 2013; 27: 3733-3738.
-
- Polkowski M, Jenssen C, Kaye P et al. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline - March 2017. Endoscopy 2017; 49: 989-1006.
Publication types
MeSH terms
Grants and funding
- No.2018A0303100024/Natural Science Foundation of Guangdong Province
- No. 81502040/National Natural Science Foundation of China
- No. JCYJ20150403101028164/Technical Research and Development Project of Shenzhen
- No. SYLY201718, SYJY201714 and SYLY201801/Three Engineering Training Funds in Shenzhen
- SZXJ2017030/Shenzhen Health Planning Commission
LinkOut - more resources