Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 May;40(6):669-673.
doi: 10.1002/pd.5655. Epub 2020 Mar 31.

Maternal low body mass index is a risk factor for fetal ductal constriction following indomethacin use among women undergoing fetal repair of spina bifida

Affiliations

Maternal low body mass index is a risk factor for fetal ductal constriction following indomethacin use among women undergoing fetal repair of spina bifida

Ahmed A Nassr et al. Prenat Diagn. 2020 May.

Abstract

Objectives: The objectives were to determine the prevalence of and to identify risk factors associated with constriction of the fetal ductus arteriosus (DA) following perioperative indomethacin use for fetal myelomeningocele (MMC) repair. Study design A retrospective chart review study included 100 consecutive fetuses who underwent fetal MMC repair between 2011 and 2018. All patients had fetal echocardiography (FE) on postoperative day (POD)#1 and 2 to detect constriction of the DA. All patients received indomethacin for tocolysis using a standardized protocol. Multivariate regression analysis was carried out to identify the predictors for fetal ductal constriction.

Results: Eighty patients met our study eligibility criteria. Median gestational age at time of surgery was 25 (24-25) weeks. Constriction of the DA was detected in 14 fetuses (17.5%). In five fetuses, this was observed on POD# 1, in seven on POD# 2, and in two on both days. The only independent risk factor for predicting DA constriction was maternal body mass index (BMI) <25 kg/m2 (P = .002).

Conclusion: Indomethacin therapy following fetal MMC surgery requires careful daily FE surveillance. The association of DA constriction and low BMI suggests that BMI-based dosing of indomethacin may be recommended for perioperative tocolysis in fetal MMC surgery.

PubMed Disclaimer

References

REFERENCES

    1. Coleman BG, Langer JE, Horii SC. The diagnostic features of spina bifida: the role of ultrasound. Fetal Diagn Ther. 2015;37(3):179-196.
    1. Zaganjor I, Sekkarie A, Tsang BL, et al. Describing the prevalence of neural tube defects worldwide: a systematic literature review. PLoS One. 2016;11(4):e0151586.
    1. Adzick NS, Thom EA, Spong CY, et al. A randomized trial of prenatal versus postnatal repair of myelomeningocele. N Engl J Med. 2011;364(11):993-1004.
    1. Novoa V, Shazly S, Araujo Júnior E, et al. Tocolysis for open prenatal repair of myelomeningocele: systematic review. J Matern Fetal Neonatal Med. 2018;1-6.
    1. Ochsenbein-Kölble N, Krähenmann F, Hüsler M, et al. Tocolysis for in utero surgery: atosiban performs distinctly better than magnesium sulfate. Fetal Diagn Ther. 2018;44:59-64.

MeSH terms

LinkOut - more resources