Subfoveal Choroidal Thickness in Pre-eclampsia
- PMID: 32011579
- DOI: 10.1097/OPX.0000000000001480
Subfoveal Choroidal Thickness in Pre-eclampsia
Abstract
Significance: To our knowledge, this is the first time a study looking at the association between subfoveal choroidal thickness (SFCT) and the parameters affecting the severity of pre-eclampsia has been reported. We provide evidence that SFCT is thicker in pre-eclamptic (PE) patients and speculate on the possible causes.
Purpose: The purposes of this study were to compare SFCT in PE, normal pregnant, and nonpregnant women using spectral domain optical coherence tomography and to correlate SFCT with severity of pre-eclampsia.
Methods: A cross-sectional, observational study was performed. A total of 150 participants were divided into three groups: group 1 (50 PE women), group 2 (50 normal pregnant women), and group 3 (50 nonpregnant healthy women). Subfoveal choroidal thickness was measured using spectral domain optical coherence tomography. Other parameters including mean arterial blood pressure (MABP), central corneal thickness, macular thickness, IOP, ocular perfusion pressure (OPP), and urine protein-to-creatinine ratio were also measured. ANOVA and Pearson correlation analysis were used to look at differences between the groups. P < .05 was considered as statistically significant.
Results: The MABP was higher in group 1 than in groups 2 and 3 (103.0 ± 12.9 vs. 83.2 ± 9.8 vs. 89.5 ± 7.2 mmHg, respectively; all P < .001). The SFCT of the PE group was higher than in groups 2 and 3 (370.7 ± 23.8 vs. 344.5 ± 30.8 vs. 315.8 ± 49.9 μm, respectively; all P < .001). There were no statistically significant differences in central corneal thickness, macular thickness, or IOP between the PE and healthy pregnant groups (all P > .05). The OPP was greater in PE patients (52.8 ± 8.5 vs. 41.9 ± 6.9 vs. 43.4 ± 5.2 mmHg, respectively; both P < .001). The SFCT was positively correlated with MABP (r = 0.464, P < .001), OPP (r = 0.495, P < .001), and urine protein-to-creatinine ratio (r = 0.635, P < .001) in the PE group.
Conclusions: Subfoveal choroidal thickness is higher in pre-eclampsia and is proportional to established markers of severity of the condition. This parameter might serve as a novel predictive marker for the severity of pre-eclampsia.
References
-
- Duru N, Ulusoy DM, Özköse A, et al. Choroidal Changes in Pre-eclampsia during Pregnancy and the Postpartum Period: Comparison with Healthy Pregnancy. Arq Bras Oftalmol 2016;79:143–6.
-
- Kim JW, Park MH, Kim YJ, et al. Comparison of Subfoveal Choroidal Thickness in Healthy Pregnancy and Pre-eclampsia. Eye (Lond) 2016;30:349–54.
-
- American College of Obstetricians and Gynecologists; Task Force on Hypertension in American College of Obstetricians and Gynecologists; Task Force on Hypertension in Pregnancy Pregnancy. Hypertension in Pregnancy. Report of the American College of Obstetricians and Gynecologists' Task Force on Hypertension in Pregnancy. Obstet Gynecol 2013;122:1122–31.
-
- Brown MC, Best KE, Pearce MS, et al. Cardiovascular Disease Risk in Women with Pre-eclampsia: Systematic Review and Meta-analysis. Eur J Epidemiol 2013;28:1–19.
-
- Zhang J, Wang H, Yu Q, et al. Enhanced Depth Imaging Optical Coherence Tomography: A New Way Measuring Choroidal Thickness in Pregnant Women. J Ophthalmol 2017;2017:8296574.
MeSH terms
LinkOut - more resources
Full Text Sources
