Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2021 Mar;31(2):664-672.
doi: 10.1177/1120672120903704. Epub 2020 Feb 4.

Outcome of autologous platelet concentrate and gas tamponade compared to heavy silicone oil tamponade in persistent macular hole surgery

Affiliations
Comparative Study

Outcome of autologous platelet concentrate and gas tamponade compared to heavy silicone oil tamponade in persistent macular hole surgery

Friederike Schaub et al. Eur J Ophthalmol. 2021 Mar.

Abstract

Purpose: Persistence represents the major reason for failure of primary macular hole repair. A variety of surgical approaches are available for treating persistent macular holes. To compare clinical outcome of re-pars plana vitrectomy combined with autologous platelet concentrate and sulfur hexafluoride 20% gas tamponade with heavy silicone oil in persistent macular hole.

Methods: Records of 48 consecutive eyes with persistent macular holes which underwent re-pars plana vitrectomy with either heavy silicone oil (35 eyes, persistent macular-hole minimum linear diameter: 518.8 ± 171.1 µm) or autologous platelet concentrate and sulfur hexafluoride 20% (13 eyes, persistent macular hole-minimum linear diameter: 454.1 ± 211.3 µm) were reviewed retrospectively. All patients underwent measurements of anatomical persistent macular hole characteristics evaluated by optical coherence tomography and visual function. Cases in which anatomical success failed after first re-pars plana vitrectomy were treated with the other surgical techniques, comparable to a cross-over design.

Results: Persistent macular hole closure rate was 57.1% with autologous platelet concentrate and sulfur hexafluoride 20% and 45.7% with heavy silicone oil (p = 0.102). Functional results were comparable when persistent macular hole closure was achieved (p ⩾ 0.741), but significantly better for the autologous platelet concentrate with sulfur hexafluoride 20% group when persistent macular hole closure failed (p = 0.019).

Conclusion: Re-pars plana vitrectomy combined with autologous platelet concentrate and sulfur hexafluoride 20% seems to achieve at least non-inferior persistent macular hole closure rates and comparable functional results when compared to heavy silicone oil, suggesting autologous platelet concentrate and sulfur hexafluoride 20% as a safe surgical alternative in persistent macular hole. Especially when persistent macular hole closure failed, autologous platelet concentrate with sulfur hexafluoride 20% seems to be superior regarding visual outcome.

Keywords: Densiron® 68; Persistent macular hole; autologous platelet concentrate; heavy silicone oil; idiopathic macular hole; internal limiting membrane peeling.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances