Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2020 Dec;96(7):E695-E702.
doi: 10.1002/ccd.28761. Epub 2020 Feb 5.

Predicting the risk of late futile outcome after transcatheter aortic valve implantation

Affiliations
Multicenter Study

Predicting the risk of late futile outcome after transcatheter aortic valve implantation

Oren Zusman et al. Catheter Cardiovasc Interv. 2020 Dec.

Abstract

Background: Transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) risk assessment is still developing and mostly concerned with mortality in the periprocedural period. We therefore sought to develop and then validate a score to predict 1-year adverse outcome.

Methods: Patients that underwent TAVI for severe AS in the Israeli registry. Patients with unsuccessful/suboptimal implantation were excluded. The cohort was split to derivation/validation cohorts by a ratio of 70:30. The outcome was defined as 1-year composite of mortality, stroke, and no improvement in NYHA class (vs. baseline). Logistic regression was used to fit the prediction model.

Results: Out of 2,440 patients meeting inclusion criteria, 276 were excluded, leaving 2,160 patients for both cohorts. At 1 year, 299 (14%) patients experienced the adverse ("futile") outcome. The derived prediction model included mean aortic valve (AV) gradient, previous pacemaker, previous oncological disease, need for diuretics, baseline NYHA class, hemoglobin and creatinine levels, and nonfemoral access site. The model's area under the curve (AUC) was 0.69 in the derivation and 0.70 in the validation cohort. Performance of other scores in the validation cohort were lower (0.60 for STS, 0.55 for Euroscore2, 0.56 for TVT score, and 0.53 for TAVI2-score, p = .03). Based on three risk tiers, patients had a low risk (20/306, 7% futility), a medium risk (50/304, 17%), and high risk (18/37, 49%) for futility.

Conclusions: The TAVI futility risk model can be used to provide further insight regarding prediction measures and/or patients' outcomes outside of the periprocedural period (NCT02023060).

Keywords: TAVI; aortic valve disease; structural heart disease intervention.

PubMed Disclaimer

References

REFERENCES

    1. Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363:1597-1607.
    1. Adams DH, Popma JJ, Reardon MJ, et al. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med. 2014;370:1790-1798.
    1. Leon MB, Smith CR, Mack MJ, et al. Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2016;374:1609-1620.
    1. Reardon MJ, Van Mieghem NM, Popma JJ, et al. Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2017;376:1321-1331.
    1. Grover FL, Vemulapalli S, Carroll JD, et al. 2016 annual report of The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. J Am Coll Cardiol. 2017;69:1215-1230.

MeSH terms

Associated data

LinkOut - more resources