Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2020 Aug;26(4):455-460.
doi: 10.1177/1591019920904421. Epub 2020 Feb 6.

A systematic review and meta-analysis of Woven EndoBridge single layer for treatment of intracranial aneurysms

Affiliations
Meta-Analysis

A systematic review and meta-analysis of Woven EndoBridge single layer for treatment of intracranial aneurysms

Sbt van Rooij et al. Interv Neuroradiol. 2020 Aug.

Abstract

Background and purpose: The Woven EndoBridge is an intrasaccular device for the treatment of intracranial aneurysms. The first generation consisted of a high-profile double-layer braid. This review aims to evaluate the outcomes of the new generation low-profile Woven EndoBridge single layer device for intracranial aneurysm treatment.

Methods: A systematic review was conducted with Medline, Embase, and Web of Science Conference Proceedings databases. The search strategy provided 589 articles, 15 articles were included.

Results: Fifteen articles were identified reporting the use of Woven EndoBridge single-layer devices in 963 aneurysms, mostly wide-necked bifurcation aneurysms. Procedural aneurysm rupture was reported in 8 of 963 patients (0.83%; 95%CI 0.39-1.66%) and thromboembolic events in 54 of 963 patients (5.61%, 95CI 4.31-7.26%). Cumulative morbidity was 2.85% (27/949, 95%CI 1.95-4.12%) and mortality 0.93% (9/963, 95%CI 0.46-1.80%). The overall rate of adequate aneurysm occlusion at last follow-up was 83.3% (613/736; 95%CI 80.4-85.8%). Retreatment was reported in 38 aneurysms in eight studies with 450 aneurysms with follow-up (38/450; 8.4%, 95CI 6.2-11.4%). In 12 studies comprising 644 aneurysms with follow-up, rebleeds occurred in three patients in three studies with mean follow-up between 3.3 and 14.4 months (0.47%, 95%CI 0.09-1.43%).

Conclusion: Woven EndoBridge single-layer is a promising new low-profile device especially for wide-neck bifurcation aneurysms, both ruptured and unruptured. No antiplatelet medication is needed which is a great advantage, especially in ruptured aneurysms. Efficacy and safety compare favorably with (stent-assisted) coiling. However, no direct comparison with other treatments is available as yet.

Keywords: Intracranial; Woven EndoBridge; aneurysm.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Flowchart search strategy.

References

    1. Rosenwasser RH, Chalouhi N, Tjoumakaris S, et al. Open vs endovascular approach to intracranial aneurysms. Clin Neurosurg 2014; 61: 121–129. - PubMed
    1. van Gijn J, Kerr RS, Rinkel GJ. Subarachnoid haemorrhage. Lancet 2007; 369: 306–318. - PubMed
    1. Li H, Pan R, Wang H, et al. Clipping versus coiling for ruptured intracranial aneurysms: a systematic review and meta-analysis. Stroke 2013; 44: 29–37. - PubMed
    1. Algra AM, Lindgren A, Vergouwen MDI, et al. Procedural clinical complications, case-fatality risks, and risk factors in endovascular and neurosurgical treatment of unruptured intracranial aneurysms: a systematic review and meta-analysis. JAMA Neurol 2019; 76: 282–293. - PMC - PubMed
    1. Armoiry X, Turjman F, Hartmann DJ, et al. Endovascular treatment of intracranial aneurysms with the WEB device: a systematic review of clinical outcomes. AJNR Am J Neuroradiol 2016; 37: 868–872. - PMC - PubMed

MeSH terms