Changes in preoperative corneal measurements following same-day intraocular pressure testing with rebound tonometry

Affiliations

Changes in preoperative corneal measurements following same-day intraocular pressure testing with rebound tonometry

Kenneth A Beckman et al. Ther Adv Ophthalmol. .

Abstract

Purpose: To evaluate the extent to which rebound tonometry affects corneal surface properties and preoperative corneal measurements.

Setting: Four cornea specialty private practices.

Design: Prospective case series.

Methods: Visual acuity testing, corneal topography, keratometry, and grading of corneal staining were performed on both eyes of 60 randomly selected, previously scheduled patients. Technicians then performed rebound tonometry on one randomly selected eye only. Immediately following, intraocular pressure measurement, corneal topography, keratometry, and corneal staining were repeated on both eyes.

Results: None of the 60 study eyes developed increased staining scores following intraocular pressure testing with the Icare ic100. For corneal staining, mean keratometry, and total corneal cylinder, no statistically significant difference was found from the first measurement to the second measurement between the study eyes and control eyes.

Conclusion: Rebound tonometry with the Icare ic100 may be used on any patient at any time during the exam without affecting the results of other tests, allowing clinicians to test intraocular pressure prior to preoperative cataract or refractive surgery measurements on the same day. This may allow for significant improvement in patient flow in the office and save patients from the cost and time of extra visits.

Keywords: Icare ic100; cataract surgery; corneal measurements; rebound tonometry; refractive surgery; same day intraocular pressure testing.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest statement: The authors declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

Figures

Figure 1.
Figure 1.
The step-by-step approach employed during the study. Fifteen patients were included from each of the four sites, for a total of 60 patients (120 eyes).

References

    1. Kass MA. Standardizing the measurement of intraocular pressure for clinical research Guidelines from the Eye Care Technology Forum. Ophthalmology 1996; 104: 184–185. - PubMed
    1. George MK, Kuriakose T, DeBroff BM. et al. The effect of Gonioscopy on keratometry and corneal surface topography. BMC Ophthalmol 2006; 6: 26. - PMC - PubMed
    1. Kontiola AI. A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmol Scand 2000; 78(2): 142–145. - PubMed
    1. Pakrou N, Gray T, Mills R, et al. Clinical comparison of the Icare tonometer and Goldmann applanation tonometry. J Glaucoma 2008; 17(1): 43–47. - PubMed
    1. Kontiola AI. Development impact tonometers for clinical use and glaucoma research. Academic Dissertation, Helsinki, Department of Ophthalmology, University of Helsinki, 2003.

LinkOut - more resources