Review
. 2020 Jul/Aug;28(4):208-212.
doi: 10.1097/CRD.0000000000000298.

The Firehawk Stent: A Review of a Novel Abluminal Groove-Filled Biodegradable Polymer Sirolimus-Eluting Stent

Affiliations
Review

The Firehawk Stent: A Review of a Novel Abluminal Groove-Filled Biodegradable Polymer Sirolimus-Eluting Stent

Yuichi Saito et al. Cardiol Rev. 2020 Jul/Aug.

Abstract

Despite recent advances in drug-eluting stent (DES) technology, late adverse events remain concerns after percutaneous coronary intervention. The persistence of polymer material on DES has been suggested as a trigger for chronic inflammation. The Firehawk, a novel DES, has a unique design with recessed abluminal grooves, to which sirolimus and biodegradable polymer are applied. The Firehawk stent is designed to minimize polymer volume and antiproliferative drug concentration to reduce inflammation and hypersensitivity reactions. Several recent trials have reported the clinical outcomes of this device. This article provides a review of the current clinical evidence concerning the Firehawk stent.

PubMed Disclaimer

References

    1. Naghavi M, Abajobir AA, Abbafati C, et al. Global, regional, and national age-sex specific mortality for 264 causes of death, 1980–2016: a systematic analysis for the global burden of Disease Study 2016. Lancet. 2017;390:1151–1210.
    1. Serruys PW, de Jaegere P, Kiemeneij F, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. N Engl J Med. 1994;331:489–495.
    1. Moses JW, Leon MB, Popma JJ, et al. SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003;349:1315–1323.
    1. Piccolo R, Bonaa KH, Efthimiou O, et al. Coronary Stent Trialists’ Collaboration. Drug-eluting or bare-metal stents for percutaneous coronary intervention: a systematic review and individual patient data meta-analysis of randomised clinical trials. Lancet. 2019;393:2503–2510.
    1. Neumann FJ, Sousa-Uva M, Ahlsson A, et al. ESC Scientific Document Group. 2018 ESC/EACTS Guidelines on myocardial revascularization. Eur Heart J. 2019;40:87–165.