. 2020 Jun;91(6):1289-1299.
doi: 10.1016/j.gie.2020.01.044. Epub 2020 Feb 6.

Role of endoscopic functional luminal imaging probe in predicting the outcome of gastric peroral endoscopic pyloromyotomy (with video)

Affiliations

Role of endoscopic functional luminal imaging probe in predicting the outcome of gastric peroral endoscopic pyloromyotomy (with video)

Kia Vosoughi et al. Gastrointest Endosc. 2020 Jun.

Abstract

Background and aims: Endoluminal functional luminal imaging probe (EndoFLIP) is an imaging tool that measures the physiologic characteristics of GI sphincters. In this study, we used EndoFLIP to evaluate the association between the pyloric physiologic measurements and the clinical outcomes of gastric peroral endoscopic myotomy (G-POEM) in patients with refractory gastroparesis.

Methods: Thirty-seven patients from 5 centers who underwent G-POEM for management of refractory gastroparesis and had EndoFLIP measurements were evaluated. Cross-sectional area (CSA), balloon pressure, and the distensibility index (DI) of the pylorus were evaluated by EndoFLIP at 40 mL and 50 mL balloon fills before and after G-POEM. One-year clinical success and change in gastric emptying study 3 months after the G-POEM procedure were compared with the EndoFLIP measurements.

Results: Clinical success was achieved in 26 (70%) patients. Post-G-POEM CSA and DI were significantly higher in the clinical success group with both 40-mL volume distension (CSA: 89.9 ± 64.8 vs 172.5 ± 71.9 mm2, P =.003; DI: 5.8 ± 4.4 vs 8.8 ± 6.1 mm2/mm Hg, P =.043) and 50-mL volume distention (CSA: 140.1 ± 89.9 vs 237.5 ± 80.3 mm2, P =.003; DI: 5.6 ± 3.3 vs 9.9 ± 6.6 mm2/mm Hg, P =.049). CSA using 40-mL volume distention with an area under the curve of 0.83 yielded a specificity of 91% and a sensitivity of 71% at a cutoff point of 154 mm2.

Conclusions: Post-G-POEM CSA of the pylorus is associated with clinical success and improvement in a gastric emptying scan after G-POEM. EndoFLIP measurements of the pylorus have the potential to be used as a tool to predict the clinical outcome of G-POEM.