. 2020 Aug;64(4):471-476.
doi: 10.1111/1754-9485.12998. Epub 2020 Feb 9.

Evaluation of a radiographer-led peripherally inserted central catheter insertion service

Affiliations

Evaluation of a radiographer-led peripherally inserted central catheter insertion service

Diederick W De Boo et al. J Med Imaging Radiat Oncol. 2020 Aug.

Abstract

Introduction: To evaluate a radiographer-led peripherally inserted central catheter (PICC) insertion service within an interventional radiology suite using ultrasound and fluoroscopic guidance.

Methods: Data from 366 consecutive PICC insertions by five trained angiography-specialized radiographers were prospectively collected over a 12-month period. For each PICC insertion, patient demographics, including past medical history of cystic fibrosis (CF), number of punctures, vein used, final tip position, contrast administration and screening time were recorded. Institutional review board approval was obtained.

Results: The overall PICC insertion success rate was 100%. Fifty-five (15%) had a known medical history of CF. Three hundred and thirty-one (90%) PICC insertions required a single puncture and 32 (9%) required two punctures. The remaining three insertions required three punctures. The basilic vein was most commonly used (69%) followed by the brachial vein (29%), and the cephalic vein was used only in 2%. Administration of contrast medium was necessary during 27 (7%) PICC insertions. Mean screening time was 10.7 s.

Conclusion: Our specifically trained, radiographer-led PICC insertion service proved to be successful. Both straightforward and complex insertions, for example in CF patients could be adequately and efficiently performed.

Keywords: angiography; intervention; vascular interventional radiology.

PubMed Disclaimer

References

    1. Smith JR, Friedell ML, Cheatham ML, Martin SP, Cohen MJ, Horowitz JD. Peripherally inserted central catheters revisited. Am J Surg 1998; 176: 208-11.
    1. Gabriel J. Care and management of peripherally inserted central catheters. Br J Nurs 1996; 5: 595-9.
    1. Loughran SC, Borzatta M. Peripherally inserted central catheters: a report of 2506 catheter days. J Parenteral Enteral Nutr 1995; 19: 133-6.
    1. Lam S, Scannel R, Roessler D, Smith MA. Peripherally inserted central catheters in an acute-care hospital. Arch Intern Med 1994; 145: 1833-7.
    1. Kyle KS, Myers JS. Peripherally inserted central catheters: development of a hospital-based program. J Intravenous Nurs 1990; 13: 287-90.