. 2020 Aug;44(8):E313-E325.
doi: 10.1111/aor.13665. Epub 2020 Mar 8.

Ventricular arrhythmias following continuous-flow left ventricular assist device implantation: A systematic review

Affiliations

Ventricular arrhythmias following continuous-flow left ventricular assist device implantation: A systematic review

Jonathan S Gordon et al. Artif Organs. 2020 Aug.

Abstract

Ventricular arrhythmias (VA) are not uncommon after continuous-flow left ventricular assist device (CF-LVAD) implantation. In this systematic review, we sought to identify the patterns of VA that occurred following CF-LVAD implantation and evaluate their outcomes. An electronic search was performed to identify all articles reporting the development of VA following CF-LVAD implantation. VA was defined as any episode of ventricular fibrillation (VF) or sustained (>30 seconds) ventricular tachycardia (VT). Eleven studies were pooled for the analysis that included 393 CF-LVAD patients with VA. The mean patient age was 57 years [95%CI: 54; 61] and 82% [95%CI: 73; 88] were male. Overall, 37% [95%CI: 19; 60] of patients experienced a new onset VA after CF-LVAD implantation, while 60% [95%CI: 51; 69] of patients had a prior history of VA. Overall, 88% of patients [95%CI: 78; 94] were supported on HeartMate II CF-LVAD, 6% [95%CI: 3; 14] on HeartWare HVAD, and 6% [95%CI: 2; 13] on other CF-LVADs. VA was symptomatic in 47% [95%CI: 28; 68] of patients and in 50% [95%CI: 37; 52], early VA (<30 days from CF-LVAD) was observed. The 30-day mortality rate was 7% [95%CI: 5; 11]. Mean follow-up was 22.9 months [95%CI: 4.8; 40.8], during which 27% [95%CI: 17; 39] of patients underwent heart transplantation. In conclusion, approximately a third of patients had new VA following CF-LVAD placement. VA in CF-LVAD patients is often symptomatic, necessitates treatment, and carries a worse prognosis.

Keywords: catheter ablation; continuous-flow left ventricle assist device; left ventricle assist device; ventricular arrhythmia; ventricular assist device; ventricular tachycardia.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Adams EE, Wrightson ML. Quality of life with an LVAD: a misunderstood concept. Heart Lung. 2018 May;47:177-83.
    1. Guzman-Gutierrez G, Shi Y, Rappelt M, Jahangir A, Thohan V. Advanced heart failure treatment options among the elderly. J Patient-cent Res Rev. 2016 Nov;3:199-206.
    1. Rodrigo ME, Molina EJ, Majure DT, Sheikh FH, Hofmeyer MR, Ruiz G, et al. Preliminary single-center experience with left anterior mini-thoracotomy for continuous-flow LVAD implantation. J Heart Lung Transplant. 2014 Apr;33:S202.
    1. Greet BD, Pujara D, Burkland D, Pollet M, Sudhakar D, Rojas F, et al. Incidence, predictors, and significance of ventricular arrhythmias in patients with continuous-flow left ventricular assist devices: a 15-year institutional experience. JACC Clin Electrophysiol. 2018 Feb;4:257-64.
    1. Kormos RL, Cowger J, Pagani FD, Teuteberg JJ, Goldstein DJ, Jacobs JP, et al. The society of thoracic surgeons intermacs database annual report: evolving indications, outcomes, and scientific partnerships. Ann Thorac Surg. 2019 Feb;107:341-53.

Publication types