One-year natural course of corneal densitometry in high myopic patients after implantation of an implantable collamer lens (model V4c)
- PMID: 32050942
- PMCID: PMC7017626
- DOI: 10.1186/s12886-020-1320-x
One-year natural course of corneal densitometry in high myopic patients after implantation of an implantable collamer lens (model V4c)
Abstract
Background: Corneal densitometry, which is also known as corneal backscattering, is a surrogate measure of corneal clarity. The purpose of the study was to investigate the changes in corneal densitometry (CD) after implanting an implantable collamer lens (ICL-V4c).
Method: Twenty-six high myopic patients (aged 29.3 ± 6.6 years, 6 males and 20 females) who underwent ICL-V4c implantation were enrolled. Intraocular pressure (IOP), corneal topography, corneal densitometry, uncorrected distance visual acuity (UCDVA), manifest refraction, and best corrected distance visual acuity (BCDVA) were evaluated pre-operatively and at 1 day, 1 week, and 1, 3, 6, and 12 months post-operatively. Endothelial cell density (ECD) was measured pre-operatively and at 3, 6, and 12 months post-operatively. The efficacy index (mean post-operative UCDVA / mean pre-operative BCDVA) and the safety index (mean post-operative BCDVA / mean pre-operative BCDVA) were evaluated at 1 month, 3 months, 6 months and 12 months post-operatively.
Results: Over the annular diameters of 0-2 mm, the pre-operative densitometry values of the anterior layer, central layer, posterior layer, and total layer were 20.1 ± 2.8, 11.8 ± 1.1, 10.5 ± 0.9 and 14.1 ± 1.5, respectively. From pre-operatively to post-operative Month 12, the values changed insignificantly (P = 0.177, P = 0.153, P = 0.543 and P = 0.207, respectively). Over the annular diameters of 2-6 mm, the pre-operative mean densitometry values were 17.9 ± 2.2, 10.5 ± 0.9, and 12.6 ± 1.2, respectively. From pre-operatively to post-operative Month 12, the values decreased to 16.5 ± 2.1, 10.0 ± 0.9, and 11.9 ± 1.2, respectively, which were similar to the pre-operative values (all P > 0.05) but significantly lower than the values obtained at post-operative Day 1 (P = 0.013, P = 0.002 and P = 0.010, respectively). The densitometry value of the posterior layer over the annular diameters of 2 to 6 mm remained unchanged (from 9.4 ± 0.7 to 9.1 ± 0.7) over time (P = 0.372). The efficacy and safety indices assessed at 12 months post-operatively were 1.04 ± 0.27 and 1.19 ± 0.23, respectively. The changes in IOP and ECD values were statistically insignificant (P = 0.896 and P = 0.968, respectively).
Conclusion: ICL-V4c implantation may be safe and efficient for high ametropia correction. The corneal densitometry values obtained over the annulus of 0-6 mm increased slightly from before the operation to post-operative Day 1 and then decreased gradually, which indicates that ICL-V4c implantation may not compromise corneal clarity.
Keywords: Corneal densitometry; Endothelial cell density; Implantable collamer lens.
Conflict of interest statement
The authors declare that they have no competing interests.
Figures



Similar articles
-
Posterior-chamber phakic implantable collamer lenses with a central port: a review.Acta Ophthalmol. 2021 May;99(3):e288-e301. doi: 10.1111/aos.14599. Epub 2020 Aug 25. Acta Ophthalmol. 2021. PMID: 32841517 Free PMC article. Review.
-
Four-year observation of the changes in corneal endothelium cell density and correlated factors after Implantable Collamer Lens V4c implantation.Br J Ophthalmol. 2021 May;105(5):625-630. doi: 10.1136/bjophthalmol-2020-316144. Epub 2020 Jun 16. Br J Ophthalmol. 2021. PMID: 32546550 Free PMC article.
-
Ten-Year Clinical Outcomes of V4c Implantable Collamer Lens Implantation: Longitudinal Analysis of Visual Acuity, Endothelial Cell Density, and Vault Dynamics.Am J Ophthalmol. 2025 Jan;269:1-10. doi: 10.1016/j.ajo.2024.08.007. Epub 2024 Aug 13. Am J Ophthalmol. 2025. PMID: 39142448
-
Long-term observation of V4c implantable collamer lenses implantation for moderate to extreme high myopia correction: five years follow-up.Eye (Lond). 2024 Jul;38(10):1933-1940. doi: 10.1038/s41433-024-03046-9. Epub 2024 Mar 22. Eye (Lond). 2024. PMID: 38519715 Free PMC article.
-
Occlusion of AquaPORT Flow in a Case of Toxic Anterior Segment Syndrome Following Implantable Collamer Lens Surgery Causing Severe Pupillary Block.J Refract Surg. 2020 Dec 1;36(12):856-859. doi: 10.3928/1081597X-20201015-01. J Refract Surg. 2020. PMID: 33296000 Review.
Cited by
-
Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.BMC Ophthalmol. 2021 May 6;21(1):199. doi: 10.1186/s12886-021-01963-x. BMC Ophthalmol. 2021. PMID: 33957891 Free PMC article.
-
Comprehensive assessment of corneal microstructural changes following V4c implantable collamer lens surgery using in vivo confocal microscopy.BMC Ophthalmol. 2024 Sep 19;24(1):408. doi: 10.1186/s12886-024-03677-2. BMC Ophthalmol. 2024. PMID: 39300374 Free PMC article.
-
A four-year observation of corneal densitometry after implantable collamer lens V4c implantation.Ann Transl Med. 2021 Apr;9(7):536. doi: 10.21037/atm-20-6628. Ann Transl Med. 2021. PMID: 33987234 Free PMC article.
-
Posterior-chamber phakic implantable collamer lenses with a central port: a review.Acta Ophthalmol. 2021 May;99(3):e288-e301. doi: 10.1111/aos.14599. Epub 2020 Aug 25. Acta Ophthalmol. 2021. PMID: 32841517 Free PMC article. Review.
-
Refractive Results With EyeCryl Phakic Toric Intraocular Lens Implantation in a Hospital in Medina, Saudi Arabia: A Retrospective Study.Cureus. 2024 Dec 31;16(12):e76656. doi: 10.7759/cureus.76656. eCollection 2024 Dec. Cureus. 2024. PMID: 39886731 Free PMC article.
References
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources