Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jul 1;58(1):177-185.
doi: 10.1093/ejcts/ezaa035.

Impact of intrapulmonary-artery septation to pulmonary vein obstruction for two-lung Fontan

Affiliations

Impact of intrapulmonary-artery septation to pulmonary vein obstruction for two-lung Fontan

Motonori Ishidou et al. Eur J Cardiothorac Surg. .

Abstract

Objectives: Patients with unbalanced pulmonary artery (PA) growth and decreased unilateral pulmonary circulation are considered unsuitable candidates for the Fontan procedure. Following our previous study on the utility of intrapulmonary-artery septation for patients with PA hypoplasia, we investigated its use in patients with pulmonary venous obstruction (PVO).

Methods: We recruited 42 patients who underwent intrapulmonary-artery septation for unilateral PA hypoplasia and/or PVO between 1998 and 2018 and classified them into no PVO or PVO group. We analysed overall survival, success of the Fontan procedure and data from catheterization and echocardiography. In PVO, we evaluated the functional lung area before the Fontan procedure and the relevance of this parameter to operative outcomes.

Results: The PVO and no-PVO group included 24 and 18 patients, respectively. One patient in the no-PVO and 6 patients in the PVO group died during follow-up; this difference was statistically significant (log-rank P = 0.040). In the no-PVO group, 15 (83%) patients achieved two-lung Fontan circulation. In the PVO group, 12 (50%) patients achieved two-lung Fontan circulation. Multivariate analysis revealed that functional lung area and shunt size [significantly larger in patients with functional lung area ≥50% in affected lung (P = 0.040)] were significant factors for successful two-lung Fontan procedure (P = 0.030).

Conclusions: Intrapulmonary-artery septation may contribute to increase functional lung area after PVO release to establish two-lung Fontan circulation in patients with PVO who have unbalanced PA growth and/or decreased unilateral pulmonary circulation.

Keywords: Fontan; Intrapulmonary-artery septation; One-lung Fontan; Pulmonary vein obstruction.

PubMed Disclaimer

MeSH terms