Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2020 Feb:45:102097.
doi: 10.1016/j.msksp.2019.102097. Epub 2019 Dec 3.

High-vs. low-tech cervical movement sense measurement in individuals with neck pain

Affiliations
Comparative Study

High-vs. low-tech cervical movement sense measurement in individuals with neck pain

Hilla Sarig Bahat et al. Musculoskelet Sci Pract. 2020 Feb.

Abstract

Objectives: To compare diagnostic ability of the clinical cervical movement sense (CCMS) test to the neck virtual reality (VR) system accuracy module.

Background: Altered cervical proprioception is common in patients with persistent neck pain (NP). Recently a simple CCMS has been found to be feasible and reliable. However, it is not known how this compares to a valid method.

Methods: Twenty participants with persistent NP and 20 healthy controls were videoed while performing the CCMS using a laser pointer and traced a zigzag pattern and then assessed using the VR accuracy module which consisted of following 8 segments in four directions. Diagnostic ability using a model from potential variables from the video analysis of number of errors and task performance time was compared to a model provided from VR data.

Results: Subjects with NP had significantly greater horizontal errors in the CCMS and VR accuracy. Both CCMS and VR measurement models utilising measurements of horizontal movement error demonstrated good diagnostic ability (AUC = 0.88, 0.91 respectively) and there was no statistical difference between the models' AUC (p = 0.7).

Conclusion: The simple clinical testing tool appears to provide a measure of cervical movement sense, similar to the established Neck VR accuracy measure. Both tools differentiated individuals with NP from controls with similar sensitivity and specificity, with some advantage to the VR. The rotational motion measures seem most suitable in the assessment of motion accuracy. CCMS has potential to be used as a simple clinical measure and warrants further research.

Keywords: Accuracy; Cervical spine; Clinical measurement; Movement sense; Sensorimotor; Virtual reality.

PubMed Disclaimer

Publication types

LinkOut - more resources