Improvement and evaluation of loop-mediated isothermal amplification combined with chromatographic flow dipstick assays for Vibrio parahaemolyticus
- PMID: 32057897
- DOI: 10.1016/j.mimet.2020.105866
Improvement and evaluation of loop-mediated isothermal amplification combined with chromatographic flow dipstick assays for Vibrio parahaemolyticus
Abstract
Vibrio parahaemolyticus, a major food-borne pathogen, is a gram-negative rod-shaped halophilic bacterium which inhabits marine environments throughout the world. It can pose a threat to humans after the consumption of raw or undercooked seafood. Fast detection is crucial for hindering and controlling V. parahaemolyticus infection. Compared with traditional methods, loop-mediated isothermal amplification (LAMP) is a simple, rapid and versatile method. It can be performed at one temperature without the need for cycling. As a new method in recent years, LAMP combined with a chromatographic flow dipstick (LFD) meets the needs of point-of-care testing without the need for special instruments. It avoids the limitations of LAMP, reduces detection time and increases detection accuracy. Our previous studies have suggested that the optimized LFD method can improve the sensitivity of LAMP detection and shorten the isothermal amplification time during the detection process. In the present study, two LAMP assays were improved to LFD methods, and a LFD targeting 16S23S rRNA gene internal transcribed spacer (ITS) of V. parahaemolyticus was developed. The lower limit for tlh, toxR, ITS LFD assays were detected as 3.1 × 100, 3.1 × 101, and 3.1 × 100 CFU respectively, whether in pure cultures or artificially contaminated food samples. The shortest amplification times at the limit of each assay were determined as 20 min, 35 min and 25 min. A heating block was used to perform two (tlh and ITS) LFD assays to detect 20 food samples. Compared to a standard method (GB 4789.7-2013 National Food Safety Standards, Food Microbiology Inspection, Vibrio parahaemolyticus test), tlh and ITS LFD assays showed more MPN (most probable number) results than that of culture. It demonstrated that the improved LFD technology can provide a simple and rapid detection method with high sensitivity and specificity for detection of V. parahaemolyticus.
Keywords: 16S–23S rRNA gene internal transcribed spacer; LAMP combined with a chromatographic flow dipstick; Tlh; Vibrio parahaemolyticus; toxR.
Copyright © 2020 Elsevier B.V. All rights reserved.
Similar articles
-
Rapid and Visual Detection of Vibrio parahaemolyticus in Aquatic Foods Using blaCARB-17 Gene-Based Loop-Mediated Isothermal Amplification with Lateral Flow Dipstick (LAMP-LFD).J Microbiol Biotechnol. 2021 Dec 28;31(12):1672-1683. doi: 10.4014/jmb.2107.07022. J Microbiol Biotechnol. 2021. PMID: 34489378 Free PMC article.
-
Development and evaluation of a loop-mediated isothermal amplification assay for rapid and sensitive detection of Vibrio parahaemolyticus.J Food Prot. 2011 Sep;74(9):1462-7. doi: 10.4315/0362-028X.JFP-10-519. J Food Prot. 2011. PMID: 21902914
-
The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Vibrio parahaemolyticus.Lett Appl Microbiol. 2011 Apr;52(4):344-51. doi: 10.1111/j.1472-765X.2011.03007.x. Epub 2011 Feb 7. Lett Appl Microbiol. 2011. PMID: 21244453
-
Loop-mediated isothermal amplification assay as a point-of-care diagnostic tool for Vibrio parahaemolyticus: recent developments and improvements.Expert Rev Mol Diagn. 2019 Mar;19(3):229-239. doi: 10.1080/14737159.2019.1571913. Epub 2019 Jan 28. Expert Rev Mol Diagn. 2019. PMID: 30657706 Review.
-
Vibrio species involved in seafood-borne outbreaks (Vibrio cholerae, V. parahaemolyticus and V. vulnificus): Review of microbiological versus recent molecular detection methods in seafood products.Crit Rev Food Sci Nutr. 2019;59(4):597-610. doi: 10.1080/10408398.2017.1384715. Epub 2017 Nov 13. Crit Rev Food Sci Nutr. 2019. PMID: 28956623 Review.
Cited by
-
Qualitative and Quantitative Detection of Potentially Virulent Vibrio parahaemolyticus in Drinking Water and Commonly Consumed Aquatic Products by Loop-Mediated Isothermal Amplification.Pathogens. 2021 Dec 22;11(1):10. doi: 10.3390/pathogens11010010. Pathogens. 2021. PMID: 35055958 Free PMC article.
-
Magnetically Localized Detection of Amplified DNA Using Biotinylated and Fluorescent Primers and Magnetic Nanoparticles.Biosensors (Basel). 2025 Mar 18;15(3):195. doi: 10.3390/bios15030195. Biosensors (Basel). 2025. PMID: 40136992 Free PMC article.
-
Unlocking the molecular realm: advanced approaches for identifying clinically and environmentally relevant bacteria.Braz J Med Biol Res. 2023 Oct 13;56:e12894. doi: 10.1590/1414-431X2023e12894. eCollection 2023. Braz J Med Biol Res. 2023. PMID: 37851790 Free PMC article.
-
Visual LAMP method for the detection of Vibrio vulnificus in aquatic products and environmental water.BMC Microbiol. 2022 Oct 21;22(1):256. doi: 10.1186/s12866-022-02656-1. BMC Microbiol. 2022. PMID: 36271365 Free PMC article.
-
Multiplex PCR-Lateral Flow Dipstick Method for Detection of Thermostable Direct Hemolysin (TDH) Producing V. parahaemolyticus.Biosensors (Basel). 2023 Jun 30;13(7):698. doi: 10.3390/bios13070698. Biosensors (Basel). 2023. PMID: 37504096 Free PMC article.
Publication types
MeSH terms
Substances
Supplementary concepts
LinkOut - more resources
Full Text Sources
Medical
Research Materials