The Utility of Serum d-Dimer for the Diagnosis of Periprosthetic Joint Infection in Revision Total Hip and Knee Arthroplasty
- PMID: 32061477
- DOI: 10.1016/j.arth.2020.01.034
The Utility of Serum d-Dimer for the Diagnosis of Periprosthetic Joint Infection in Revision Total Hip and Knee Arthroplasty
Abstract
Background: There is scarce and contradicting evidence supporting the use of serum d-dimer for the diagnosis of periprosthetic joint infection in revision total hip (THA) and knee (TKA) arthroplasty. Therefore, the purpose of this study is to test the accuracy of serum d-dimer against the 2013 International Consensus Meeting (ICM) criteria.
Methods: A retrospective review was performed on a consecutive series of 172 revision THA/TKA surgeries performed by 3 fellowship-trained surgeons at a single institution (August 2017 to May 2019) and that had d-dimer performed during their preoperative workup. Of this cohort, 111 (42 THAs/69 TKAs) cases had complete 2013 ICM criteria tests and were included in the final analysis. Septic and aseptic revisions were categorized per 2013 ICM criteria ("gold standard") and compared against serum d-dimer using an established threshold (850 ng/mL). Sensitivity, specificity, likelihood ratios, and positive/negative predictive values were determined. Independent t-tests, Fisher's exact tests, chi-squared tests, and receiver operating characteristic curve analysis were performed.
Results: There was no statistically significant difference in baseline demographics between septic and aseptic cases per 2013 ICM criteria. When compared to ICM criteria, d-dimer demonstrated high sensitivity (95.9%) and negative predictive value (90.9%) but low specificity (32.3%), positive predictive value (52.8%), and overall, poor accuracy (61%) to diagnose periprosthetic joint infection. Positive likelihood ratio was 1.42 while negative likelihood ratio was 0.13. The area under the curve (AUC) was 0.742.
Conclusion: Serum d-dimer has poor accuracy to discriminate between septic and aseptic cases using a described threshold in the setting of revision THA and TKA.
Keywords: PJI; periprosthetic joint infection; serum d-dimer; total hip arthroplasty; total knee arthroplasty.
Copyright © 2020 Elsevier Inc. All rights reserved.
MeSH terms
Substances
LinkOut - more resources
- Full Text Sources
- Medical
 
        