Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1988 Sep;13(9):1012-8.
doi: 10.1097/00007632-198809000-00008.

Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement

Affiliations

Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement

J N Weinstein et al. Spine (Phila Pa 1976). 1988 Sep.

Abstract

The increased popularity of pedicle fixation prompted research to address two issues: the reliability and validity of roentgenograms as a technique for evaluating the success of pedicle fixation, and the effects of surgical factors on successful fixation. Thus, does approach--the point and angle of screw insertion, surgeon experience, practice, level of the spine involved, and screw size--effect success of pedicle fixation? Eight fresh thoracolumbar spines were harvested and cleaned of all soft tissues. Two surgeons, one more experienced in pedicle fixation than the other, used two pedicle fixation approaches (Weinstein and Roy-Camille) on both the left and right sides at levels T11-S1 of each specimen. All screws were placed under anteroposterior (AP) and lateral c-arm control. For specimens 1 to 3, 5.5 mm screws were used at T11-L1, and 7.0 mm screws at L2-S1. Unacceptable failure rates at L2 and L3 for the first three specimens resulted in a change of instrumentation for the remaining specimens, with 5.5 mm screws used at T11-L3 and 7.0 mm screws at L4-S1. When surgeons completed the fixations for a specimen, AP and lateral roentgenograms were taken and both surgeons independently evaluated the films to assess the success of each fixation. Failure was defined as evidence of any cortical perforation on any side of the pedicle in or outside of the spinal canal. After completing the roentgenogram evaluation, the specimen was transected in the midline, and the success of each pedicle fixation was evaluated by visual/tactile inspection. There were no disagreements between surgeons on the visual/tactile evaluations of the specimens.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources