Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Oct;64(4):424-430.
doi: 10.1016/j.jpor.2019.11.007. Epub 2020 Feb 13.

2D/3D accuracies of implant position after guided surgery using different surgical protocols: A retrospective study

Affiliations

2D/3D accuracies of implant position after guided surgery using different surgical protocols: A retrospective study

C Monaco et al. J Prosthodont Res. 2020 Oct.

Abstract

Purpose: To compare the 2D and 3D positional accuracy of four guided surgical protocols using an analysis of linear and angular deviations.

Methods: DICOM and .STLs files obtained from a CBCT and a digital impression were superimposed with software to plan implant position. Fifty-six patients were subdivided into 4 groups: FGA group (template support [Ts]: teeth [T]; bed preparation [Bp]: fully guided [FG]; implant insertion [Ii]: 3D template [3Dt]; device [D]: manual adapter [MA], FGM group (Ts: T; Bp: FG; Ii: 3Dt; D: fully guided mounter [FGM]), PG group (Ts: T; Bp: FG; Ii: manual; D: none) and MS group (Ts: mucosa; Bp: FG; Ii: 3Dt; D: FGM). The position of 120 implants was assessed by superimposing the planned and final position recorded with a digital impression.

Results: In FGA group, 3D deviations were 0.92 ± 0.52 mm at the implant head and 1.14 ± 0.54 mm at the apex, and the angular deviation (ang. dev.) was 2.45 ± 1.24°. In FGM group, were 0.911 ± 0.44 mm (head) and 1.11 ± 0.54 mm (apex), and the ang. dev. was 2.73 ± 1.96°. In PG group, were 0.95 ± 0.47 mm (head) and 1.17 ± 0.488 mm (apex), and the ang. dev. was 3.71 ± 1.67°. In MS group, were 1.15 ± 0.45 mm (head) and 1.42 ± 0.45 mm (apex), and the ang. dev. was 4.19 ± 2.62°. Ang. dev. of MS group was different from the other groups (P < 0.05).

Conclusions: Guided surgery showed a sufficient accuracy.

Keywords: Angular deviation; Digital impression; Guided surgery; Linear deviation; Surgical guides.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no conflict of interest.

Substances

LinkOut - more resources