Dimensions of the Lateral Malleolar Fossa and Its Potential Violation With Lateral Distal Fibular Plate Fixation
- PMID: 32077963
- DOI: 10.3928/01477447-20200213-04
Dimensions of the Lateral Malleolar Fossa and Its Potential Violation With Lateral Distal Fibular Plate Fixation
Abstract
A previously undescribed pitfall of lateral distal fibular locking plates is the risk of violating the lateral malleolar fossa (MF). No previous study has described the dimensions of this fossa. All cases using a lateral distal fibular plate for a fibula fracture from December 2012 to December 2015 (n=365) at a single institution were reviewed. Screws that violated the medial fibular cortical density corresponding to the MF were identified as "at-risk" screws. Available preoperative computed tomography (CT) scans were reviewed (n=69) to measure MF dimensions. Of 365 patients, 115 (31.5%) patients had distal fibular screws at risk of MF violation. There were no significant differences between MF violation and non-violation groups in terms of age, sex, open fracture, syndesmotic fixation, and Weber classification. The MF dimensions were measured on CT scans. Mean height was 12.96 mm (SD, 2.09 mm; range, 9.0-17.3 mm). Mean width was 7.52 mm (SD, 1.37 mm; range, 4.2-10.4 mm). Mean depth was 8.32 mm (SD, 1.59 mm; range, 5.3-11.8 mm). Mean ratio of MF to total fibular width was 0.46 mm (SD, 0.07 mm; range, 0.3-0.65 mm). Mean MF to total fibular depth was 0.42 mm (SD, 0.07 mm; range, 0.28-0.58 mm). There was a difference in dimensions of patients with screws at risk of MF violation compared with those without (MF height: 13.77 vs 12.56, P=.02; MF width: 7.98 vs 7.30, P=.05; MF to fibula width ratio: 0.49 vs 0.44, P=.01; MF to fibula depth ratio: 0.43 vs 0.42, P=.05). The MF violation is a previously unreported but potentially prevalent pitfall of lateral distal fibular plate fixation. Surgeons should be aware of the MF size and exhibit caution when placing screws in the distal locking holes during fibula fixation. [Orthopedics. 2020;43(3):e141-e146.].
Copyright 2020, SLACK Incorporated.
Similar articles
-
Lateral malleolus closed reduction and internal fixation with intramedullary fibular rod using minimal invasive approach for the treatment of ankle fractures.Foot Ankle Surg. 2019 Feb;25(1):79-83. doi: 10.1016/j.fas.2017.08.008. Epub 2017 Sep 7. Foot Ankle Surg. 2019. PMID: 29409300
-
Implant Failure Rates and Cost Analysis of Contoured Locking Versus Conventional Plate Fixation of Distal Fibula Fractures.Orthopedics. 2017 Nov 1;40(6):e1024-e1029. doi: 10.3928/01477447-20171012-05. Epub 2017 Oct 23. Orthopedics. 2017. PMID: 29058759
-
Does the Use of Locking Screws Decrease the Rate of Hardware Removal in Ankle Fractures?Foot Ankle Spec. 2019 Dec;12(6):518-521. doi: 10.1177/1938640018823056. Epub 2019 Jan 4. Foot Ankle Spec. 2019. PMID: 30607989
-
[Minimally invasive fixation of distal fibular fractures with intramedullary nailing].Oper Orthop Traumatol. 2021 Apr;33(2):104-111. doi: 10.1007/s00064-021-00702-1. Epub 2021 Mar 16. Oper Orthop Traumatol. 2021. PMID: 33728477 Review. German.
-
Reinforced fixation of distal fibula fractures in elderly patients; A meta-analysis of biomechanical studies.Clin Biomech (Bristol). 2016 Jul;36:14-20. doi: 10.1016/j.clinbiomech.2016.05.006. Epub 2016 May 11. Clin Biomech (Bristol). 2016. PMID: 27195736 Review.
Cited by
-
The safe zone of distal fibula was determined based on the classification of lateral malleolus fossa.J Orthop Surg Res. 2023 Sep 22;18(1):714. doi: 10.1186/s13018-023-04194-6. J Orthop Surg Res. 2023. PMID: 37736730 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical