Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1977 Mar;39(3):341-6.
doi: 10.1016/s0002-9149(77)80086-6.

New approach to interpretation of technetium-99m pyrophosphate scintigraphy in detection of acute myocardial infarction: clinical assessment of diagnostic accuracy

New approach to interpretation of technetium-99m pyrophosphate scintigraphy in detection of acute myocardial infarction: clinical assessment of diagnostic accuracy

D S Berman et al. Am J Cardiol. 1977 Mar.

Abstract

A modified classification for interpreting technetium-99m pyrophosphate scintigrams defines the 2+ diffuse pattern of tracer uptake as equlvocal rather than positive for acute myocardial infarction. Results of scintigraphy using this classification were compared with results of standard diagnostic tests for myocardial infarction in 235 patients admitted to a coronary care unit with acute chest pain. Of 81 patients with acute transmural infarction by standard clinical, electrocardiographic and serum enzyme criteria, 76 had a positive, 5 an equivocal and none a negative scintigram. Of 18 with acute nontransmural infarction by standard criteria, 7 had a positive, 9 an equivocal and 2 a negative scintigram. This it was uncommon for a patient with acute myocardial infarction, transmural or nontransmural, to have a definitely negative technetium-99m pyrophosphate study. Ten patients had equivocal evidence of infarction by standard criteria. Of the remaining 126 patients with no evidence of acute myocardial infarction by standard criteria, 87 had a negative, 35 an equivocal and 4 a definitely positive scintigram. Thus the definitely positive scintigraphic pattern was relatively highly specific for acute myocardial infarction. If the 2+ pattern had been considered positive, the specificity of the technique would have been greatly decreased. Computer processing strengthened observer certainty of the visual impression but changed the scintigraphic evaluation in only eight cases. Thus, use of an equivocal pattern renders technetium-99m pyrophosphate imaging both an extremely sensitive and specific method for detecting acute myocardial infarction.

PubMed Disclaimer

Publication types

LinkOut - more resources