Electrically evoked brainstem potentials in cochlear implant patients with multi-electrode stimulation
- PMID: 3209488
- DOI: 10.1016/0378-5955(88)90057-3
Electrically evoked brainstem potentials in cochlear implant patients with multi-electrode stimulation
Abstract
The electrically evoked brainstem potential was measured in cochlear implant patients with Symbion multichannel electrode system. In the first experiment, electrodes within the implant were stimulated individually and the responses and sensitivity across electrodes and across subjects were evaluated. The typical response waveform consisted of a series of three peaks, the most prominent occurring at approximately 4 ms after stimulus onset. The amplitude of the largest peak typically showed an orderly increase with increasing current level while latency changes were relatively small. In the second experiment, two electrodes were stimulated simultaneously in order to evaluate the relative independence of the neural populations being stimulated by the different electrode pairs. The responses were compared when two electrode pairs were stimulated simultaneously with current pulses in phase and when the same electrodes were stimulated with current pulses inverted relative to each other. Both stimulation conditions showed similar growth in response amplitude with level but different sensitivity. The differences in sensitivity between these two conditions may be indicative of the degree of overlap in the stimulated neural populations.
Similar articles
-
Auditory brainstem activity and development evoked by apical versus basal cochlear implant electrode stimulation in children.Clin Neurophysiol. 2007 Aug;118(8):1671-84. doi: 10.1016/j.clinph.2007.04.030. Epub 2007 Jun 27. Clin Neurophysiol. 2007. PMID: 17588811
-
Characteristics of electrically evoked 'auditory' brainstem responses elicited with the nucleus 22-electrode intracochlear implant.Scand Audiol. 1990;19(4):263-7. doi: 10.3109/01050399009070782. Scand Audiol. 1990. PMID: 2150110
-
Using evoked compound action potentials to assess activation of electrodes and predict C-levels in the Tempo+ cochlear implant speech processor.Ear Hear. 2010 Feb;31(1):134-45. doi: 10.1097/AUD.0b013e3181bdb88f. Ear Hear. 2010. PMID: 19838116
-
Electrically evoked brainstem responses in cochlear implant recipients.Otolaryngol Head Neck Surg. 1987 Jan;96(1):34-8. doi: 10.1177/019459988709600106. Otolaryngol Head Neck Surg. 1987. PMID: 3118294
-
Electrically evoked potentials in cochlear implant subjects.Laryngoscope. 1986 Feb;96(2):178-85. doi: 10.1288/00005537-198602000-00009. Laryngoscope. 1986. PMID: 3753737
Cited by
-
The Electrically Evoked Compound Action Potential: From Laboratory to Clinic.Front Neurosci. 2017 Jun 23;11:339. doi: 10.3389/fnins.2017.00339. eCollection 2017. Front Neurosci. 2017. PMID: 28690494 Free PMC article. Review.
-
Spatial channel interactions in cochlear implants.J Neural Eng. 2011 Aug;8(4):046029. doi: 10.1088/1741-2560/8/4/046029. Epub 2011 Jul 13. J Neural Eng. 2011. PMID: 21750370 Free PMC article.
-
Comparison of a Traditional and Novel Evoked Compound Action Potentials Recording Approach and Evoked Auditory Brainstem Responses in Pediatric Cochlear Implants Users.J Int Adv Otol. 2018 Dec;14(3):353-358. doi: 10.5152/iao.2018.5591. J Int Adv Otol. 2018. PMID: 30541708 Free PMC article.
-
Considerations for Fitting Cochlear Implants Bimodally and to the Single-Sided Deaf.Trends Hear. 2022 Jan-Dec;26:23312165221108259. doi: 10.1177/23312165221108259. Trends Hear. 2022. PMID: 35726211 Free PMC article. Review.
-
Comparison of Interaural Electrode Pairing Methods for Bilateral Cochlear Implants.Trends Hear. 2015 Dec 1;19:2331216515617143. doi: 10.1177/2331216515617143. Trends Hear. 2015. PMID: 26631108 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical