Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Dec;24(6):1387-1396.
doi: 10.1007/s10029-020-02144-3. Epub 2020 Feb 25.

Laparoscopic intraperitoneal onlay mesh (IPOM) repair using n-butyl-2-cyanoacrylate (Liquiband Fix8™) for mesh fixation: learning experience and short-medium term results

Affiliations

Laparoscopic intraperitoneal onlay mesh (IPOM) repair using n-butyl-2-cyanoacrylate (Liquiband Fix8™) for mesh fixation: learning experience and short-medium term results

P Wilson. Hernia. 2020 Dec.

Abstract

Aim: The purpose of this study was to evaluate a novel hernia repair glue fixation device (LiquibandFix8™) in laparoscopic IPOM repair for incisional hernias.

Methods: All ventral incisional hernia patients requiring laparoscopic IPOM repair were included in the study. A retrospective review of the data was performed.

Results: 137 patients underwent 138 laparoscopic IPOM repairs for incisional hernias using n-butyl-2-cyanoacrylate (LiquibandFix8™) for mesh fixation over a 40-month period by a single experienced laparoscopic surgeon. There were 70 males and 67 females, median age 54 years (range 23-80 years). Defects were predominantly midline n = 123/138 (89%) and were closed by transfascial sutures in 126/138 (91%) prior to IPOM repair (IPOM plus). Mesh fixation was successful in all 138 repairs. Synthetic meshes (Symbotex™ [polyester/collagen composite, Medtronic] n = 80, and Dynamesh® [polypropylene/PVDF composite, FEG Textiltechnik mbH] n = 5) and biologic meshes (Surgimend® [bovine collagen dermal matrix, Integra] n = 53) were used. Median follow-up was 32 months (range 12-48 months). There were 16 adverse events in 12 patients (9%): conversion to open surgery (inadvertent enterotomy) 2 (1.5%), bladder perforation 1, intraperitoneal bleeding 2, port-site haematoma 2, port site wound infection 1, post-op ileus 2, chest infection 1, seroma 1 (1%), hernia recurrence 3 (2%) and chronic pain 2 (1.5%).

Conclusion: This retrospective study shows that mesh fixation in laparoscopic IPOM using cyanoacrylate glue with the Liquiband Fix8™ device is feasible, safe, easy to learn, and is associated with a low risk of seroma, hernia recurrence and chronic pain with short-medium term follow-up.

Keywords: Biologic mesh; Cyanoacrylate glue; Laparoscopic IPOM repair; Mesh fixation.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. Pierce RA, Spitler JA, Frisella MM, Brunt LM (2007) Pooled data analysis of laparoscopic vs. open ventral hernia repair: 14 years of patient data accrual. Surg Endosc 21:378 - DOI
    1. Suwa K, Okamoto T, Yanaga K (2016) Closure versus non-closure of fascial defects in laparoscopic ventral and incisional hernia repairs: a review of the literature. Surg Today 46(7):764–773 - DOI
    1. Reynvoet E, Deschepper E, Rogiers X, Troisi R, Berrevoet F (2014) Laparoscopic ventral hernia repair: is there an optimal mesh fixation technique? A systematic review. Langenbecks Arch Surg 399(1):55–63 - DOI
    1. Bansal VK, Asuri K, Panaiyadiyan S, Subramanian R, Ramachandran R, Sagar R, Misra MC (2016) Comparison of absorbable versus nonabsorbable tackers in terms of long-term outcomes, chronic pain, and quality of life after laparoscopic incisional hernia repair: a randomized study. Surg Laparosc Endosc Percutaneous Tech 26(6):476–483 - DOI
    1. Golash V (2008) Large gut fistula due to a protruding spiral tacker after laparoscopic repair of a ventral hernia. Oman Med J 23:50–52 - PubMed - PMC

LinkOut - more resources