Effect of heparinization of catheters on pulmonary artery oximetry
- PMID: 3210068
- DOI: 10.1007/BF01621817
Effect of heparinization of catheters on pulmonary artery oximetry
Abstract
A clinical study was performed in two phases to determine whether pulmonary artery oximeter catheters that were impregnated or bonded with heparin would affect the accuracy of measurements of in vivo mixed venous oxygen saturation (Sv-O2). In phase 1, 40 patients were catheterized with either a heparin-impregnated or a plain pulmonary artery catheter. Blood was sampled at random times to correlate in vivo with in vitro Sv-O2 measurements. In phase 2, 16 patients who were not receiving systemic heparin therapy or aspirin and who had no coagulopathies were catheterized with either a heparin-bonded or a plain pulmonary artery catheter in a blinded order. In phase 1, a total of 364 blood samples were obtained from 40 patients. Linear regression analysis of the pooled data demonstrated y = 0.98x - 0.01, r = 0.93, P less than 0.001, and n = 141 with heparin-impregnated catheters; and y = 0.87x + 8.0, r = 0.81, P less than 0.001, and n = 223 with plain catheters. The mean difference (in vivo minus in vitro) revealed a similar error (-1.3 +/- 0.4 versus -1.4 +/- 0.4, respectively, mean +/- SE). The 95% confidence limits of an individual value (+/- 8.1 versus +/- 12.3) suggested slightly greater accuracy with heparin-impregnated catheters. In phase 2, a total of 134 blood samples were obtained from 16 patients. Linear regression analysis showed nearly equal performance with heparin-bonded and plain catheters (r = 0.97 versus r = 0.98, respectively) with similar slopes (1.0 versus 1.1, respectively) but different intercepts (-0.6 versus -8.4, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Effect of carboxyhemoglobin on the accuracy of mixed venous oximetry monitors in dogs.Crit Care Med. 1994 Jul;22(7):1181-5. doi: 10.1097/00003246-199407000-00022. Crit Care Med. 1994. PMID: 8026210
-
A laboratory comparison of three pulmonary artery oximetry catheters.Anesthesiology. 1994 Jul;81(1):245-53. doi: 10.1097/00000542-199407000-00031. Anesthesiology. 1994. PMID: 8042792
-
[The accuracy of 4 different oximeters for continuous monitoring of mixed venous oxygen saturation during abdominal aortic surgery].Anaesthesist. 1992 Feb;41(2):71-5. Anaesthesist. 1992. PMID: 1562095 Clinical Trial. German.
-
Retinal oximetry and systemic arterial oxygen levels.Acta Ophthalmol. 2018 Nov;96 Suppl A113:1-44. doi: 10.1111/aos.13932. Acta Ophthalmol. 2018. PMID: 30460761 Review.
-
Types of urethral catheters for management of short-term voiding problems in hospitalized adults: a short version Cochrane review.Neurourol Urodyn. 2008;27(8):738-46. doi: 10.1002/nau.20645. Neurourol Urodyn. 2008. PMID: 18951451 Review.
References
MeSH terms
Substances
LinkOut - more resources
Medical