Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2020 Jun;39(6):573-579.
doi: 10.1016/j.healun.2020.02.007. Epub 2020 Feb 13.

Early experience with the HeartMate 3 continuous-flow ventricular assist device in pediatric patients and patients with congenital heart disease: A multicenter registry analysis

Affiliations
Multicenter Study

Early experience with the HeartMate 3 continuous-flow ventricular assist device in pediatric patients and patients with congenital heart disease: A multicenter registry analysis

Matthew J O'Connor et al. J Heart Lung Transplant. 2020 Jun.

Abstract

Background: The HeartMate 3 ventricular assist device (VAD) is a newer centrifugal continuous-flow VAD used for bridge-to-transplant and destination therapy in adults. However, there is limited experience regarding its use in children and adults with complex congenital heart disease (CHD).

Methods: The Advanced Cardiac Therapies Improving Outcomes Network (ACTION) is a multicenter learning network comprised of pediatric hospitals implanting VADs in children and adults with complex CHD. We examined the outcomes of patients undergoing HeartMate 3 implantation at an ACTION center between December 2017 and September 2019.

Results: The HeartMate 3 was implanted in 35 patients at 9 ACTION centers, with a median age of 15.7 (8.8-47.3) years, median weight of 65.7 (19.1-114.1) kg, and median body surface area (BSA) of 1.74 (0.78-2.36) m2. Of the cohort, 14 patients (40%) weighed <60 kg. Diagnoses included dilated cardiomyopathy (63%), dilated cardiomyopathy in neuromuscular disease (20%), and CHD (17%). Of those with CHD, most had a Fontan circulation. With a median 78 days of follow-up, there was 1 death on device (97% survival); 20 out of 35 (57%) underwent transplantation with no post-transplantation mortality. There were no episodes of stroke or pump thrombosis.

Conclusions: Use of the HeartMate 3 in ACTION centers was associated with a low incidence of mortality and adverse events. Patients as small as 19 kg (BSA 0.78 m2) were successfully implanted and supported, indicating that this device may be appropriate for older children and small adults.

Keywords: children; congenital; mechanical circulatory support; pediatric; ventricular assist device.