Abstract
Background: The prognosis of patients with untreated cardiac implantable electronic device (CIED) infection is poor. Whether removal of all leads by a successful transvenous lead extraction (TLE) procedure changes the prognosis is unclear.
Objective: To identify predictors of mortality in patients with CIED infection despite successful TLE.
Methods: Retrospective single-center analysis of prospectively collected database from consecutive patients undergoing TLE at our center. Predictors for mortality were identified and a score predicting high mortality rate was calculated.
Results: A total of 371 consecutive patients underwent TLE, of whom 337 (90.8%) had complete hardware removal. Most were extracted due to infectious causes (81.3%). Approximately one-third (35%) died during a mean follow-up of 1056 ± 868 days. There was significantly higher mortality observed in the infectious group. Multivariate logistic regression models for infectious group only identified creatinine and albumin measurements as risk markers for 30 days mortality (odds ratio [OR], 1.68; 95% confidence interval [CI], 1.19-2.38; P = .003 and OR, 0.4; 95% CI, 0.16-0.97; P = .039, respectively). A risk score was created based on cutoff values of creatinine ≥2md/dL (1 point) and albumin ≤3.5 g/dL (1 point). A value of 2 points predicted a 50% chance of 30-day mortality and a 75% chance of 1-year mortality (P < .0001 for both).
Conclusions: Creatinine and albumin can be used as a combined risk score to successfully identify patients at risk of death despite undergoing a successful TLE procedure for infectious reasons. This score could help decision making when contemplating on conservative antibiotic treatment vs TLE.
Keywords: albumin; creatinine; infection; lead extraction; mortality; risk score.
© 2020 Wiley Periodicals, Inc.
Comment in
-
Quantifying risk after transvenous lead extraction.J Cardiovasc Electrophysiol. 2020 May;31(5):1163-1165. doi: 10.1111/jce.14435. Epub 2020 Mar 16. J Cardiovasc Electrophysiol. 2020. PMID: 32141663 No abstract available.
References
REFERENCES
-
- Brignole M, Auricchio A, Baron-Esquivias G, et al. 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace. 2013;15:1070-1118.
-
- Epstein AE, Dimarco JP, Ellenbogen KA, et al. ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: executive summary. Heart Rhythm. 2008;5:934-955.
-
- Bradshaw PJ, Stobie P, Knuiman MW, Briffa TG, Hobbs MS. Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing population. Open Heart. 2014;1:e000177.
-
- Mond HG, Proclemer A. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009-a World Society of Arrhythmia's project. Pacing Clin Electrophysiol. 2011;34:1013-27.
-
- Voigt A, Shalaby A, Saba S. Continued rise in rates of cardiovascular implantable electronic device infections in the United States: temporal trends and causative insights. Pacing Clin Electrophysiol. 2010;33:414-419.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous