Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiac and vascular diseases. Since its introduction in the late 1980s, quantitative flow imaging with MRI has become a routine part of standard-of-care cardiothoracic and vascular MRI for the assessment of pathological changes in blood flow in patients with cardiovascular disease. More recently, time-resolved flow imaging with velocity encoding along all three flow directions and three-dimensional (3D) anatomic coverage (4D flow MRI) has been developed and applied to enable comprehensive 3D visualization and quantification of hemodynamics throughout the human circulatory system. This article provides an overview of the use of 4D flow applications in different cardiac and vascular regions in the human circulatory system, with a focus on using 4D flow MRI in cardiothoracic and cerebrovascular diseases.
Keywords: 4D flow; blood flow; hemodynamics; magnetic resonance imaging.
Similar articles
-
4D flow imaging with MRI.Cardiovasc Diagn Ther. 2014 Apr;4(2):173-92. doi: 10.3978/j.issn.2223-3652.2014.01.02. Cardiovasc Diagn Ther. 2014. PMID: 24834414 Free PMC article. Review.
-
Four-dimensional-flow Magnetic Resonance Imaging of the Aortic Valve and Thoracic Aorta.Radiol Clin North Am. 2020 Jul;58(4):753-763. doi: 10.1016/j.rcl.2020.02.008. Epub 2020 May 12. Radiol Clin North Am. 2020. PMID: 32471542 Review.
-
Quantitative Analysis of Vortical Blood Flow in the Thoracic Aorta Using 4D Phase Contrast MRI.PLoS One. 2015 Sep 29;10(9):e0139025. doi: 10.1371/journal.pone.0139025. eCollection 2015. PLoS One. 2015. PMID: 26418327 Free PMC article.
-
4D Flow MRI of the Thoracic Aorta.Radiol Cardiothorac Imaging. 2025 Aug;7(4):e240532. doi: 10.1148/ryct.240532. Radiol Cardiothorac Imaging. 2025. PMID: 40838825 Review.
-
Four-dimensional flow magnetic resonance imaging in cirrhosis.World J Gastroenterol. 2016 Jan 7;22(1):89-102. doi: 10.3748/wjg.v22.i1.89. World J Gastroenterol. 2016. PMID: 26755862 Free PMC article. Review.
Cited by
-
Right ventricular energetic biomarkers from 4D Flow CMR are associated with exertional capacity in pulmonary arterial hypertension.J Cardiovasc Magn Reson. 2022 Dec 1;24(1):61. doi: 10.1186/s12968-022-00896-8. J Cardiovasc Magn Reson. 2022. PMID: 36451198 Free PMC article.
-
4D Flow MR Imaging of the Left Atrium: What is Non-physiological Blood Flow in the Cardiac System?Magn Reson Med Sci. 2022 Mar 1;21(2):293-308. doi: 10.2463/mrms.rev.2021-0137. Epub 2022 Feb 19. Magn Reson Med Sci. 2022. PMID: 35185085 Free PMC article.
-
Flow-based method demonstrates improved accuracy for calculating wall shear stress in arterial flows from 4D flow MRI data.J Biomech. 2023 Jan;146:111413. doi: 10.1016/j.jbiomech.2022.111413. Epub 2022 Dec 9. J Biomech. 2023. PMID: 36535100 Free PMC article.
-
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update.J Cardiovasc Magn Reson. 2023 Jul 20;25(1):40. doi: 10.1186/s12968-023-00942-z. J Cardiovasc Magn Reson. 2023. PMID: 37474977 Free PMC article. Review.
-
Carotid artery hemodynamics and geometry as predictors of cerebral small vessel disease: insights from 4D flow imaging.Neuroradiology. 2025 Apr;67(4):961-975. doi: 10.1007/s00234-025-03569-2. Epub 2025 Mar 3. Neuroradiology. 2025. PMID: 40029370
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical