. 2018 Mar 6;3(1):61-65.
doi: 10.14744/eej.2018.75047. eCollection 2018.

Comparison of PathFile and ProFinder Systems to Create a Glide Path in Curved Root Canals

Affiliations

Comparison of PathFile and ProFinder Systems to Create a Glide Path in Curved Root Canals

Ruth Pérez Alfayate et al. Eur Endod J. .

Abstract

Objective: Root canal shaping is as important as irrigation and filling when attempting to obtain a high success rate in endodontic treatment. The creation of a glide path before the use of rotary instruments reduces the risk of posterior iatrogenic errors. The objective of the present study was to evaluate instrumentation time and root canal transport after using 2 different glide path rotary systems.

Methods: In total, 60 mesiobuccal root canals of mandibular molars, with curvature angles between 11° and 82°, were standardized to measure 15 mm. The specimens were divided into 2 groups, depending on their angles of curvature (11º-38º and 39º-82º), and further divided into 4 groups (n=15). Two groups were instrumented using the PathFile system and the other 2 using the ProFinder system. The angle and radius of curvature were measured at the most abrupt angle of curvature before and after instrumentation. Both measurements were analyzed and compared using AutoCAD software to determine canal transportation. Curvature angles were compared using Student's t test and the radii of curvature using the Wilcoxon test. The time for instrumentation was also evaluated using Student's t tests.

Results: There were no statistically significant differences between the two systems with respect to root canal transport (P>0.05); however, the ProFinder system took a longer time to create a glide path (P=0.004).

Conclusion: Both systems were equally effective in creating a glide path; however, the PathFile system proved to be faster than the ProFinder system.

Keywords: Curved root canals; PathFile; ProFinder; glide path.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest: The authors deny any conflicts of interest related to this study.

Figures

Figure 1
Figure 1
Flowchart of the methodology
Figure 2
Figure 2
(a-c) Images of calculation of the angle of curvature with the AutoCAD 2008. (a) Calculation of the angle and radius of curvature with the computer informatics program. (b) Calculation of pre-instrumentation. (c) Calculation of post-instrumentation

Similar articles

Cited by

References

    1. Pruett JP, Clement DJ, Carnes DL., Jr Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod. 1997;23(2):77–85. - PubMed
    1. Setzer FC, Kwon TK, Karabucak B. Comparison of apical transportation between two rotary file systems and two hybrid rotary instrumentation sequences. J Endod. 2010;36(7):1226–9. - PubMed
    1. Roland DD, Andelin WE, Browning DF, Hsu GH, Torabinejad M. The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments. J Endod. 2002;28(7):543–5. - PubMed
    1. Patiño PV, Biedma BM, Liébana CR, Cantatore G, Bahillo JG. The influence of a manual glide path on the separation rate of NiTi rotary instruments. J Endod. 2005;31(2):114–6. - PubMed
    1. Blum JY, Cohen A, Machtou P, Micallef JP. Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments. Int Endod J. 1999;32(1):24–31. - PubMed

LinkOut - more resources