Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Sep;39(4):261-264.
doi: 10.1016/j.hansur.2020.02.004. Epub 2020 Mar 20.

Wrist ROM measurements using smartphone photography: Reliability and validity

Affiliations

Wrist ROM measurements using smartphone photography: Reliability and validity

M Ge et al. Hand Surg Rehabil. 2020 Sep.

Abstract

No one has validated measuring the wrist's active range of motion (ROM) using smartphone images in patients. It is not known whether pathological factors affect the accuracy of this measurement technique. The purpose of this study was to assess if smartphone photography is as reliable and valid as manual goniometry for measuring wrist joint ROM. We reviewed 38 wrists in 38 patients (21 women and 17 men) with a mean age of 45 years (range, 26-60). Smartphones were used to take digital photos of injured wrists at extremes of wrist motion, including flexion, extension, radial and ulnar deviation. The mean difference in measured ROM between the two measurement methods (digital photos and handheld goniometer) was compared using Student's t test and the relationship determined using Pearson correlation coefficients. Bland-Altman analysis was used to define the limits of agreement (LOA). No significant difference was found when comparing the wrist ROM in the four positions using manual goniometry and digital measurements from photos taken by a surgeon. Between the goniometer measurements and digital photos taken by a surgeon, the Pearson coefficients were high, with most being above 0.8 for the four positions. The Pearson coefficients also show the smartphone measurements were highly precise. There was high reliability between the photographs taken by surgeons and by patients, as well as high interobserver reliability. Smartphone photography is a reliable and valid method to measure wrist joint ROM in patients. This measurement method can be used to measure outcomes.

Keywords: Measurement; Mesure; Mobilité; Motion; Poignet; Smartphone; Wrist.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

LinkOut - more resources