Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2020 Aug;27(4):289-297.
doi: 10.1080/09286586.2020.1741010. Epub 2020 Mar 16.

Topometric and Tomographic Evaluation of Subclinical Keratoconus

Affiliations
Observational Study

Topometric and Tomographic Evaluation of Subclinical Keratoconus

Mustafa Koc et al. Ophthalmic Epidemiol. 2020 Aug.

Abstract

Purpose: To investigate the corneal topometric and tomographic findings that can be used in the diagnosis of subclinical keratoconus.

Methods: A retrospective cohort study. The study group was selected from patients with clinically evident keratoconus in one eye and subclinical keratoconus without evident topographic findings in fellow eye. The age-matched control group was selected from patients who were candidates for laser in situ keratomileusis (LASIK) and did not develop ectasia after LASIK surgery at least 1-year follow-up. All subjects underwent topographic, topometric and tomographic (Belin-Ambrósio Enhanced Ectasia Display III) analyses via a Pentacam HR rotating Scheimpflug camera (Oculus, Germany, version 1.20r.98) before LASIK surgery.

Results: The study group consisted of 151 patients (69 male and 82 female, mean age of 24.8 ± 7.2 years) and the control group also consisted of 150 patients (70 male and 80 female, mean age of 26.0 ± 6.3 years). There were statistically significant differences in all measured topometric (p˂.05) and tomographic (p˂.001) parameters between the eyes with subclinical keratoconus and those of the control group. In discriminating eyes with subclinical keratoconus from normal eyes, final D showed the highest area under curve value (0.858, sensitivity 85.2%, specificity 66.7%), followed by maximum pachymetric progression index (0.809, sensitivity 81.9%, specificity 69.4%) and average pachymetric progression index (0.796, sensitivity 81.9%, specificity 68.1%) in receiver operating characteristic analysis.

Conclusion: Topometric and tomographic parameters might be useful for early detection of keratoconus, but the sensitivity and specificity of any parameter are not high enough to be used alone.

Keywords: Keratoconus; sensitivity; specificity; subclinical keratoconus; tomography; topometry.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources