X-ray-transmission computed tomography
- PMID: 321930
- DOI: 10.1118/1.594381
X-ray-transmission computed tomography
Abstract
The immediate goal of clinically based x-ray-transmission computed tomography (CT) is to provide a measurement of the x-ray linear attenuation coefficient in cross section with the ultimate goal of impacting on patient management and care. To do this with the accuracy needed for clinical goals requires the careful integration of x-ray physics, detector technology, and mathematical reconstruction theory. Performance evaluation and quality assurance are necessary adjuncts to a CT scanning program. A number of investigative studies are underway.
Similar articles
-
Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography.Phys Med Biol. 2010 Sep 21;55(18):5383-400. doi: 10.1088/0031-9155/55/18/008. Epub 2010 Aug 24. Phys Med Biol. 2010. PMID: 20736494
-
Measurement of electron density in dual-energy x-ray CT with monochromatic x rays and evaluation of its accuracy.Med Phys. 2008 Nov;35(11):4924-32. doi: 10.1118/1.2987738. Med Phys. 2008. PMID: 19070226
-
A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography.Med Phys. 2014 Mar;41(3):031901. doi: 10.1118/1.4863507. Med Phys. 2014. PMID: 24593719
-
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.Semin Nucl Med. 2003 Jul;33(3):166-79. doi: 10.1053/snuc.2003.127307. Semin Nucl Med. 2003. PMID: 12931319 Review.
-
Search for isotropic resolution in CT from conventional through multiple-row detector.Radiographics. 2002 Jul-Aug;22(4):949-62. doi: 10.1148/radiographics.22.4.g02jl14949. Radiographics. 2002. PMID: 12110725 Review.
Cited by
-
Two-stage deep learning network-based few-view image reconstruction for parallel-beam projection tomography.Quant Imaging Med Surg. 2022 Apr;12(4):2535-2551. doi: 10.21037/qims-21-778. Quant Imaging Med Surg. 2022. PMID: 35371942 Free PMC article.
-
X-ray-induced acoustic computed tomography: 3D X-ray absorption imaging from a single view.Sci Adv. 2024 Dec 6;10(49):eads1584. doi: 10.1126/sciadv.ads1584. Epub 2024 Dec 6. Sci Adv. 2024. PMID: 39642225 Free PMC article.
-
Development and Validation of a Nomogram for Axillary Lymph Node Metastasis Risk in Breast Cancer.J Cancer. 2024 Oct 7;15(18):6122-6134. doi: 10.7150/jca.100651. eCollection 2024. J Cancer. 2024. PMID: 39440057 Free PMC article.
-
CT whole-body scanning and scintigraphy in children with malignant tumours. A comparative retrospective study.Pediatr Radiol. 1979 Apr 19;8(2):103-7. doi: 10.1007/BF00974000. Pediatr Radiol. 1979. PMID: 450483
-
Cross-Sectional Area Measurement Techniques of Soft Tissue: A Literature Review.Orthop Surg. 2020 Dec;12(6):1547-1566. doi: 10.1111/os.12757. Epub 2020 Sep 15. Orthop Surg. 2020. PMID: 32930465 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources