Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jun;46(6):876-882.
doi: 10.1111/jog.14243. Epub 2020 Mar 23.

Efficacy of intraoperative wireless ultrasonography for uterine incision among patients with adherence findings in placenta previa

Affiliations

Efficacy of intraoperative wireless ultrasonography for uterine incision among patients with adherence findings in placenta previa

Min J Choi et al. J Obstet Gynaecol Res. 2020 Jun.

Abstract

Aim: We evaluated the effectiveness of intraoperative wireless ultrasonography in determining the location of uterine incision during cesarean delivery in patients with placenta previa who have sonographic adherence findings in order to assess intraoperative blood loss and maternal morbidity.

Methods: A prospective study using wireless sonography, including 15 patients with previa, was conducted among women with singleton pregnancies who delivered by cesarean section between August 1, 2017, and August 30, 2019. Retrospective study for the control group included 32 patients with placenta previa who underwent cesarean section between January 1, 2016, and July 31, 2017, without wireless sonography. Patients with previa who had adherence findings in prenatal sonography were included in both groups. Logistic regression was used to identify the association between massive intraoperative bleeding loss and use of wireless ultrasound sonography.

Results: Intraoperative blood loss was significantly reduced in the study group compared to that in the control group (P = 0.009). The hospital stay was significantly shorter in the study group compared to the control group (5 days vs 6 days, P < 0.001). The use of intraoperative wireless sonography (P = 0.01) had a significant association with massive intraoperative hemorrhage in multivariable analysis.

Conclusion: Our study is the first study to apply a wireless ultrasound sonography device in women with placenta previa during cesarean section to examine maternal morbidity. This latest wireless ultrasound sonography device is advantageous for uterine incision guidance in women with placenta previa and improves maternal morbidity by reducing intraoperative hemorrhage.

Keywords: intraoperative hemorrhage; intraoperative sonography; placenta previa; uterine incision; wireless ultrasonography.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Cunningham FGLK, Bloom SL. Obstetrical hemorrhage. In: dashe JS, Hoffman B, Casey BM, Spong CY (eds). Williams Obstetrics, 25th edn. New York: McGraw-Hill, 2018; 773.
    1. Kollmann M, Gaulhofer J, Lang U, Klaritsch P. Placenta praevia: Incidence, risk factors and outcome. J Matern Fetal Neonatal Med 2016; 29: 1395-1398.
    1. Baba Y, Matsubara S, Ohkuchi A et al. Anterior placentation as a risk factor for massive hemorrhage during cesarean section in patients with placenta previa. J Obstet Gynaecol Res 2014; 40: 1243-1248.
    1. Frank H, Boehm M, Arthur C, Fleischer MD, Jeffrey M, Barrett MD. Sonographic placental localization in the determination of the site of uterine incision for placenta previa. J Ultrasound Med 1982; 1: 311-314.
    1. Gibbins KJ, Einerson BD, Varner MW, Silver RM. Placenta previa and maternal hemorrhagic morbidity. J Matern Fetal Med 2017; 31: 494-499.

LinkOut - more resources