Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Mar 26;20(1):121.
doi: 10.1186/s12886-020-01389-x.

Establishing a normative database for quantitative pupillometry in the pediatric population

Affiliations

Establishing a normative database for quantitative pupillometry in the pediatric population

Sanket S Shah et al. BMC Ophthalmol. .

Abstract

Background: Pupillary evaluation is a crucial element of physical exams. Noting size, reactivity, and consensual response is critical in assessing for optic nerve dysfunction. We aim to establish normative data for scotopic pupillary size and function in the pediatric population in a clinical setting.

Methods: Pupillometry was obtained prospectively for consecutive, normal patients < 18 years old being evaluated by Lurie Children's Ophthalmology. Quantitative data included maximum (MAX) and minimum (MIN) diameters, constriction percentage (CON), latency (LAT), average (ACV) and maximum (MCV) constriction velocities, average dilation velocity (ADV), and 75% recovery time (T75). Iris color was noted as light, intermediate, or dark.

Results: 196 eyes of 101 participants (42.6% male, ages 1-17 years, average age 10.3 years) were analyzed. Mean MAX was 6.6 mm (5.1-8.1 mm 95% CI); MIN was 4.7 mm (3.1-6.1 mm 95% CI); CON was 30% (17-42 95% CI); LAT was 230 milliseconds (160-300 ms 95% CI); ACV was 3.70 mm/sec (2.21-5.18 mm/sec 95% CI); and ADV was 0.88 mm/sec (0.38-1.38 mm/sec 95% CI). Age had a positive correlation with MAX, MIN, and CON. 84.2 and 95.8% of participants showed resting pupil asymmetry of ≤0.5 mm and ≤ 1.0 mm, respectively.

Conclusions: Quantitative pupillometry can be a useful tool for screening pediatric patients. We sought to establish normative data in this group. We found males to have significantly greater MCV and CON than females (p < 0.05). Also, age had a positive correlation with MAX, MIN, and CON.

Keywords: Normative; Pediatric screening; Pupillometry; Pupils.

PubMed Disclaimer

Conflict of interest statement

The authors declare that they have no competing interests.

References

    1. Karavanaki K, Davies AG, Hunt LP, Morgan MH, Baum JD. Pupil size in diabetes. Arch Dis Child. 1994;71(6):511–515. doi: 10.1136/adc.71.6.511. - DOI - PMC - PubMed
    1. Pena MM, Donaghue KC, Fung AT, Bonney M, Schwingshandl J, Howard NJ, et al. The prospective assessment of autonomic nerve function by pupillometry in adolescents with type 1 diabetes mellitus. Diabet Med. 1995;12(10):868–873. doi: 10.1111/j.1464-5491.1995.tb00388.x. - DOI - PubMed
    1. Schwingshandl J, Simpson JM, Donaghue K, Bonney MA, Howard NJ, Silink M. Pupillary abnormalities in type I diabetes occurring during adolescence. Comparisons with cardiovascular reflexes. Diabetes Care. 1993;16(4):630–633. doi: 10.2337/diacare.16.4.630. - DOI - PubMed
    1. Boev AN, Fountas KN, Karampelas I, Boev C, Machinis TG, Feltes C, et al. Quantitative pupillometry: normative data in healthy pediatric volunteers. J Neurosurg. 2005;103(6 Suppl):496–500. - PubMed
    1. Taylor WR, Chen JW, Meltzer H, Gennarelli TA, Kelbch C, Knowlton S, et al. Quantitative pupillometry, a new technology: normative data and preliminary observations in patients with acute head injury. Technical note. J Neurosurg. 2003;98(1):205–213. doi: 10.3171/jns.2003.98.1.0205. - DOI - PubMed