Fully Untethered Battery-free Biomonitoring Electronic Tattoo with Wireless Energy Harvesting

Affiliations

Fully Untethered Battery-free Biomonitoring Electronic Tattoo with Wireless Energy Harvesting

José Alberto et al. Sci Rep. .

Abstract

Bioelectronics stickers that interface the human epidermis and collect electrophysiological data will constitute important tools in the future of healthcare. Rapid progress is enabled by novel fabrication methods for adhesive electronics patches that are soft, stretchable and conform to the human skin. Yet, the ultimate functionality of such systems still depends on rigid components such as silicon chips and the largest rigid component on these systems is usually the battery. In this work, we demonstrate a quickly deployable, untethered, battery-free, ultrathin (~5 μm) passive "electronic tattoo" that interfaces with the human skin for acquisition and transmission of physiological data. We show that the ultrathin film adapts well with the human skin, and allows an excellent signal to noise ratio, better than the gold-standard Ag/AgCl electrodes. To supply the required energy, we rely on a wireless power transfer (WPT) system, using a printed stretchable Ag-In-Ga coil, as well as printed biopotential acquisition electrodes. The tag is interfaced with data acquisition and communication electronics. This constitutes a "data-by-request" system. By approaching the scanning device to the applied tattoo, the patient's electrophysiological data is read and stored to the caregiver device. The WPT device can provide more than 300 mW of measured power if it is transferred over the skin or 100 mW if it is implanted under the skin. As a case study, we transferred this temporary tattoo to the human skin and interfaced it with an electrocardiogram (ECG) device, which could send the volunteer's heartbeat rate in real-time via Bluetooth.

PubMed Disclaimer

Conflict of interest statement

The authors declare no competing interests.

Figures

Figure 1
Figure 1
Disposable Electronic Tattoo with energy harvesting coil for fully untethered wireless ECG monitoring. (A) The ECG patch includes energy harvesting coil, two skin interfacing bio-potential electrodes, and a re-utilisable battery-free electronic circuit for data acquisition, processing and communication. (i) Example of the “Data-By-Demand” system. By approaching the mobile device, the electronic tattoo receives the required energy and wirelessly communicates physiological data such as heartbeat and body temperature to the same mobile device (ii). (B) Steps for fabrication of the printed ultrathin disposable electronic tattoo. Printing the circuit pattern using an ordinary laser printer and black toner over transfer tattoo paper (i). A silver epoxy is deposited and rubbed with a fabric (ii) rubbing is continued until the excess is removed. Ag bonds selectively to the laser printed pattern (iii). Trace amount of Liquid metal is deposited (iv), spread (v), and cleaned with a weak acetic acid solution (vi). LM wets selectively the parts with the Ag. (vii). The circuit is applied to the skin and is wet by a fabric. The backing paper is removed (viii), and the ultrathin polymer carrier with the circuit facing to the skin is transferred to the skin (ix).
Figure 2
Figure 2
Main components of the ECG acquisition and transmission board: (A) scheme of the circuit; (B) (i) picture of the box of ECG acquisition system and (ii) of the PCB board; (C) WPT resonant circuit used.
Figure 3
Figure 3
Transmitter coil (A), fabricated receiver coil (B) and receiver coil drawing (C) with dimensions (D).
Figure 4
Figure 4
Comparison between the “tattoo electrodes”, Ag/AgCl electrodes and Stainless Steel electrodes. (A) Acquired signal during ECG and EMG comparison of the electrode-skin impedance for different electrodes, average and std of 5 acquisitions, for Ag/AgCl electrodes (i), Stainless Steel electrodes (ii) and “tattoo electrodes” (iii). (B) The model used in the analysis (i), the value of RS (ii), Rd (iii) and Cd (iv). (C) Comparison of Signal to Noise ratio during ECG acquisition for 5 measurements (i), and the skin-electrode impedance (ii). The representation of a conformable interface vs a non-conforming interface (iii).
Figure 5
Figure 5
Concept for an implanted biomedical device with a near-field energy harvesting coil (A), schematics of the experiment performed to simulate the effect of porcine skin in between the receiver and transmitter coil (B) and results of the simulation comparing the power output with and without pork skin in between the coils (C).
Figure 6
Figure 6
Schematics of the experiment performed to simulate the effect of human skin under the receiver coil (A) and results of efficiency measurements with and without human skin under the receiver coil (B).
Figure 7
Figure 7
Example of the prototype of the printed electronic tattoo ready to transfer (A) and the full ECG monitoring circuit transferred to the human body (B).
Figure 8
Figure 8
Scheme of the experimental setup built in the laboratory.
Figure 9
Figure 9
Picture of the built prototype transferred to the skin being used to transmit the ECG information (A) and the ECG signal received by the computer with the beats-per-minute (BPM) information (B).

References

    1. Haahr, R. G., Duun, S., Thomsen, E. V., Hoppe, K. & Branebjerg, J. A wearable “electronic patch” for wireless continuous monitoring of chronically diseased patients. In 2008 5th International Summer School and Symposium on Medical Devices and Biosensors, 66–70, 10.1109/ISSMDBS.2008.4575018 (IEEE, 2008).
    1. Wu, C.-C. et al. A pliable and batteryless real-time ECG monitoring system-in-a-patch. in VLSI Design, Automation and Test(VLSI-DAT) 1–4, 10.1109/VLSI-DAT.2015.7114521 (IEEE, 2015).
    1. Akalin Acar Z, Acar CE, Makeig S. Simultaneous head tissue conductivity and EEG source location estimation. Neuroimage. 2016;124:168–180. doi: 10.1016/j.neuroimage.2015.08.032. - DOI - PMC - PubMed
    1. Tavakoli, M., Benussi, C. & Lourenco, J. L. Single channel surface EMG control of advanced prosthetic hands: A simple, low cost and efficient approach. Expert Syst. Appl. 79 (2017).
    1. Tavakoli M, Benussi C, Alhais Lopes P, Osorio LB, de Almeida AT. Robust hand gesture recognition with a double channel surface EMG wearable armband and SVM classifier. Biomed. Signal Process. Control. 2018;46:121–130. doi: 10.1016/j.bspc.2018.07.010. - DOI

Publication types