Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Apr:109:110570.
doi: 10.1016/j.msec.2019.110570. Epub 2019 Dec 19.

Microporous carbon fibers as electroconductive immobilization matrixes: Effect of their structure on operational parameters of laccase-based amperometric biosensor

Affiliations

Microporous carbon fibers as electroconductive immobilization matrixes: Effect of their structure on operational parameters of laccase-based amperometric biosensor

Taras Kavetskyy et al. Mater Sci Eng C Mater Biol Appl. 2020 Apr.

Abstract

In this study, we describe the fabrication of sensitive biosensor for the detection of phenolic substrates using laccase immobilized onto two types of microporous carbon fibers (CFs). The main characteristics of microporous CFs used for preparation of biosensors are given. Two CFs were characterized by different specific surface area, CFA (<1 m2·g-1) and CFB (1448 m2·g-1), but with comparable size of the micropores estimated by positron annihilation lifetime spectroscopy. The structural analysis was shown that CFA is formed by thin interwoven fibers forming a highly porous structure, as well as CFB - by granular formations with uneven edges that shape a cellulose membrane of lower porosity. The results of amperometric analysis revealed that the laccase-bound CFs possesses better electrochemical behavior for laccase than non-modified rod carbon electrodes (control). Using chronoamperometric analysis, the operational parameters of the CFs-modified bioelectrodes were compared to control bioelectrodes. The bioelectrodes based on CFs have demonstrated 2.4-2.7 folds enhanced maximal current at substrate saturation (Imax) values, 1.2-1.4 folds increased sensitivity and twice wide linearity compared with control bioelectrodes. The sensitivity of the developed CFs-based bioelectrodes was improved compared with the laccase-bound electrodes, described in literature. The developed biosensor was tested for catechol analysis in the real communal wastewater sample.

Keywords: Amperometric biosensor; Catechol; Laccase; Microporous carbon fibers; Positron annihilation; Wastewater analysis.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Supplementary concepts

LinkOut - more resources