Observational Study
. 2020 Aug;64(7):953-960.
doi: 10.1111/aas.13586. Epub 2020 Apr 14.

B-Lines for the assessment of extravascular lung water: Just focused or semi-quantitative?

Affiliations
Observational Study

B-Lines for the assessment of extravascular lung water: Just focused or semi-quantitative?

Armin Seibel et al. Acta Anaesthesiol Scand. 2020 Aug.

Abstract

Background: B-lines as typical artefacts of lung ultrasound are considered as surrogate measurement for extravascular lung water. However, B-lines develop in the sub-pleural space and do not allow assessment of the whole lung. Here, we present data from the first observational multi-centre study focusing on the correlation between a B-lines score and extravascular lung water in critically ill patients suffering from a variety of diseases.

Patients and methods: In 184 adult patients, 443 measurements were obtained. B-lines were counted and expressed in a score which was compared to extravascular lung water, measured by single-indicator transpulmonary thermodilution. Appropriate correlation coefficients were calculated and receiver operating characteristics (ROC-) curves were plotted.

Results: Overall, B-lines score was correlated with body weight-indexed extravascular lung water characterized by r = .59. The subgroup analysis revealed a correlation coefficient in patients without an infection of r = .44, in those with a pulmonary infection of r = .75 and in those with an abdominal infection of r = .23, respectively. Using ROC-analysis the sensitivity and specificity of B-lines for detecting an increased extravascular lung water (>10 mL/kg) was 63% and 79%, respectively. In patients with a P/F ratio <200 mm Hg, sensitivity and specificity to predict an increased extravascular lung water was 71% and 93%, respectively.

Conclusions: Assessment of B-lines does not accurately reflect actual extravascular lung water. In presence of an impaired oxygenation, B-lines may reliably indicate increased extravascular lung water as cause of the oxygenation disorders.

Keywords: B-Lines; extravascular lung water; interstitial syndrome; lung edema; oxygenation index; transpulmonary thermodilution.

PubMed Disclaimer

References

REFERENCES

    1. Roguin A, Behar DM, Ami HB, et al. Long-term prognosis of acute pulmonary oedema - an ominous outcome. Eur J Heart Fail. 2000;2:137-144.
    1. Martin GS, Bernard GR. Airway and lung in sepsis. Intensive Care Med. 2001;27:63-79.
    1. Garutti I, Sanz J, Olmedilla L, et al. Extravascular lung water and pulmonary vascular permeability index measured at the end of surgery are independent predictors of prolonged mechanical ventilation in patients undergoing liver transplantation. Anesth Analg. 2015;121(3):736-745.
    1. Kor DJ, Warner DO, Carter RE, et al. Extravascular lung water and pulmonary vascular permeability index as markers predictive of postoperative acute respiratory distress syndrome: a prospective cohort investigation. Crit Care Med. 2015;43:665-673.
    1. Jozwiak M, Silva S, Persichini R, et al. Extravascular lung water is an independent prognostic factor in patients with acute respiratory distress syndrome. Crit Care Med. 2013;41:472-480.

Publication types

Associated data

LinkOut - more resources