Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2020 May;38(5):783-790.
doi: 10.1097/HJH.0000000000002335.

Catheter-based renal denervation as adjunct to pulmonary vein isolation for treatment of atrial fibrillation: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Catheter-based renal denervation as adjunct to pulmonary vein isolation for treatment of atrial fibrillation: a systematic review and meta-analysis

Christian Ukena et al. J Hypertens. 2020 May.

Abstract

Objective: Renal denervation (RDN) can reduce sympathetic activity and blood pressure (BP) in hypertensive patients, which both have an impact on atrial fibrillation. We performed a systematic meta-analysis on the effects of renal denervation (RDN) in addition to pulmonary vein isolation (PVI) in patients with atrial fibrillation.

Methods: All published randomized controlled trials investigating the effects of RDN as adjunctive treatment to PVI for rhythm control of atrial fibrillation were included. Primary endpoint was recurrence of atrial fibrillation after 12 months on average.

Results: A total of six randomized controlled studies including 689 patients with hypertension and symptomatic atrial fibrillation were included. In five studies, patients had uncontrolled BP despite prescription of an average of three antihypertensive agents. PVI was performed with irrigated radio-frequency catheters in 387 patients, and in 302 with cryoballoon. Cardiac ablation catheters were used for RDN in 78% of all cases. In the remaining 22%, RDN was performed using a designated, nonirrigated radio-frequency catheter system. After 12 months, the mean odds ratio for recurrence of atrial fibrillation for PVI with RDN compared with PVI alone was 0.43 (95% confidence interval 0.32-0.59). After RDN, BP was reduced significantly whereas no changes were reported in the PVI-only groups. No relevant complications associated to RDN were documented.

Conclusion: This meta-analysis supports the concept of RDN as an adjunctive treatment for atrial fibrillation. Further studies with standardized PVI and RDN procedures are needed.

PubMed Disclaimer

Comment in

References

    1. Lip GYH, Coca A, Kahan T, Boriani G, Manolis AS, Olsen MH, et al. Hypertension and cardiac arrhythmias: executive summary of a consensus document from the European Heart Rhythm Association (EHRA) and ESC Council on Hypertension, endorsed by the Heart Rhythm Society (HRS), Asia-Pacific Heart Rhythm Society (APHRS), and Sociedad Latinoamericana de Estimulacion Cardiaca y Electrofisiologia (SOLEACE). Eur Heart J Cardiovasc Pharmacother 2017; 3:235–250.
    1. Kannel WB, Wolf PA, Benjamin EJ, Levy D. Prevalence, incidence, prognosis, and predisposing conditions for atrial fibrillation: population-based estimates. Am J Cardiol 1998; 82 (8A):2N–9N.
    1. Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga L, et al. 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart rhythm 2017; 14:e275–e444.
    1. Bohm M, Linz D, Urban D, Mahfoud F, Ukena C. Renal sympathetic denervation: applications in hypertension and beyond. Nat Rev Cardiol 2013; 10:465–476.
    1. Linz D, Ukena C, Mahfoud F, Neuberger HR, Böhm M. Atrial autonomic innervation: a target for interventional antiarrhythmic therapy? J Am Coll Cardiol 2014; 63:215–224.

Substances

LinkOut - more resources