Effect of changes in heart rate on pressure half time in normally functioning mitral valve prostheses
- PMID: 3224053
- PMCID: PMC1224891
- DOI: 10.1136/hrt.60.6.502
Effect of changes in heart rate on pressure half time in normally functioning mitral valve prostheses
Abstract
To test the validity of a relation between the pressure half time and the diastolic time interval, previously shown in a pulse duplication system, eight patients with prosthetic mitral valves and permanent pacemaker systems were studied. Recordings were made from the apex by continuous wave or pulsed Doppler echocardiography at heart rates between 75 and 150 beats/min. The pressure half time was found to be closely correlated with the diastolic time interval although there was individual variation and in three prostheses the pressure half time attained a plateau when the diastolic time interval was more than 300 ms. It is likely that the orifice area is the main controller of pressure half time where there is stenosis of the prosthesis, but that other factors such as ventricular or atrial compliance and the diastolic time interval may modify or obscure the effect of orifice area in normally functioning prosthetic valves.
Similar articles
-
Doppler sonographic evaluation of mechanical and bioprosthetic mitral valve prostheses during exercise with a rate corrected pressure half time.Br Heart J. 1992 Jun;67(6):466-9. doi: 10.1136/hrt.67.6.466. Br Heart J. 1992. PMID: 1622696 Free PMC article.
-
Mitral pressure half-time: is it a valid measure of orifice area in artificial heart valves?J Heart Valve Dis. 1993 Sep;2(5):571-7. J Heart Valve Dis. 1993. PMID: 8269170 Review.
-
[Genesis and clinical significance of an apical diastolic rumble in patients with mitral Björk-Shiley valve: a Doppler echocardiographic study].J Cardiol. 1990;20(1):147-57. J Cardiol. 1990. PMID: 2093747 Japanese.
-
Prosthetic mitral valve motion during cardiac dysrhythmias as determined by echocardiography.Am J Cardiol. 1983 Mar 15;51(6):996-1004. doi: 10.1016/s0002-9149(83)80180-5. Am J Cardiol. 1983. PMID: 6829479
-
[Doppler echocardiography in the examination of normally functioning artificial mitral and aortic valves].Orv Hetil. 1991 Nov 24;132(47):2591-7. Orv Hetil. 1991. PMID: 1956682 Review. Hungarian.
Cited by
-
Assessment of normal and abnormal prosthetic mitral valves by Doppler echocardiography. Doppler in prosthetic mitral valves.Int J Card Imaging. 1990-1991;6(1):11-21. doi: 10.1007/BF01798428. Int J Card Imaging. 1990. PMID: 2286769
-
Limitations of Doppler ultrasound in the assessment of the function of prosthetic mitral valves.Br Heart J. 1990 Mar;63(3):189-94. doi: 10.1136/hrt.63.3.189. Br Heart J. 1990. PMID: 2183860 Free PMC article.
-
Doppler sonographic evaluation of mechanical and bioprosthetic mitral valve prostheses during exercise with a rate corrected pressure half time.Br Heart J. 1992 Jun;67(6):466-9. doi: 10.1136/hrt.67.6.466. Br Heart J. 1992. PMID: 1622696 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous