Prospective assessment of reproducibility of three-dimensional ultrasound for fetal biometry
- PMID: 32241702
- DOI: 10.1016/j.diii.2020.03.004
Prospective assessment of reproducibility of three-dimensional ultrasound for fetal biometry
Abstract
Purpose: To compare fetal ultrasound measurements performed by two observers with different levels of experience and evaluate the potential contribution of the use of three-dimensional (3D) ultrasound on repeatability, reproducibility and agreement of two-dimensional (2D) and 3D-derived measurements.
Materials and methods: Two observers (one senior and one junior) measured head circumference (HC), abdominal circumference (AC) and femur length (FL) in 33 fetuses (20 to 40 weeks of gestation). Each observer performed two series of 2D measurements and two series of 3D measurements (i.e., measurements derived from triplane volume processing). Measurements were converted into Z-scores according to gestational age. Variability between the different series of measurements was studied using Bland-Altmann plots and intra-class correlation coefficients (ICC).
Results: Agreement with the 2D measurements of the senior observer was higher in 3D than in 2D for the junior observer (systematic differences of -0.4, -0.2 and -0.8 Z-score vs. -0.1, -0.1 and -0.6 for HC, AC and FL on 2D and 3D datasets, respectively). The use of 3D ultrasound improved junior observer repeatability (ICC=0.94, 0.88, 0.90 vs. 0.94, 0.94 and 0.96 for HC, AC and FL in 2D and 3D, respectively). The reproducibility was greater using the junior observer 3D datasets (ICC=0.75, 0.60 and 0.45 vs. 0.79, 0.89 and 0.63 for HC, AC and FL, respectively).
Conclusion: The use of 3D ultrasound improves the consistency of the measurements performed by a junior observer and increases the overall repeatability and reproducibility of measurements performed by observers with different levels of experience.
Keywords: , Prenatal; Gestational age; Reproducibility of results; Three-dimensional ultrasound; Ultrasonography.
Copyright © 2020 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Similar articles
-
Fetal biometry by an inexperienced operator using two- and three-dimensional ultrasound.Ultrasound Obstet Gynecol. 2010 May;35(5):566-71. doi: 10.1002/uog.7600. Ultrasound Obstet Gynecol. 2010. PMID: 20183864
-
Volumetric (3D) imaging reduces inter- and intraobserver variation of fetal biometry measurements.Ultrasound Obstet Gynecol. 2009 Apr;33(4):447-52. doi: 10.1002/uog.6321. Ultrasound Obstet Gynecol. 2009. PMID: 19277977
-
Inter-observer variability in fetal biometric measurements.Taiwan J Obstet Gynecol. 2018 Feb;57(1):32-39. doi: 10.1016/j.tjog.2017.12.006. Taiwan J Obstet Gynecol. 2018. PMID: 29458900
-
Fetal biometry: how well can offline measurements from three-dimensional volumes substitute real-time two-dimensional measurements?Ultrasound Obstet Gynecol. 2013 Nov;42(5):560-70. doi: 10.1002/uog.12410. Epub 2013 Oct 2. Ultrasound Obstet Gynecol. 2013. PMID: 23335102
-
Biometry and fetal weight estimation by two-dimensional and three-dimensional ultrasonography: an intraobserver and interobserver reliability and agreement study.Ultrasound Obstet Gynecol. 2012 Aug;40(2):186-93. doi: 10.1002/uog.10146. Epub 2012 Jul 3. Ultrasound Obstet Gynecol. 2012. PMID: 22102507
Cited by
-
Artificial intelligence assistance for fetal development: evaluation of an automated software for biometry measurements in the mid-trimester.BMC Pregnancy Childbirth. 2024 Feb 23;24(1):158. doi: 10.1186/s12884-024-06336-y. BMC Pregnancy Childbirth. 2024. PMID: 38395822 Free PMC article.
-
Fetal dose in pregnant CT patients: a comparison of four software packages.Eur Radiol. 2025 Apr 25. doi: 10.1007/s00330-025-11594-1. Online ahead of print. Eur Radiol. 2025. PMID: 40278874
-
Rapid and automatic assessment of early gestational age using computer vision and biometric measurements based on ultrasound video.Quant Imaging Med Surg. 2022 Apr;12(4):2247-2260. doi: 10.21037/qims-21-837. Quant Imaging Med Surg. 2022. PMID: 35371935 Free PMC article.
-
7-Tesla magnetic resonance imaging for monitoring microstructural changes in the lenticulostriate artery-neural complex in patients with hypertension.Quant Imaging Med Surg. 2024 Dec 5;14(12):8308-8319. doi: 10.21037/qims-24-869. Epub 2024 Nov 11. Quant Imaging Med Surg. 2024. PMID: 39698607 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources