Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2020 Aug:216:55-58.
doi: 10.1016/j.ajo.2020.03.030. Epub 2020 Apr 2.

Accuracy of Swept-Source Optical Coherence Tomography and Ultrasound Biomicroscopy for Evaluation of Posterior Lens Capsule in Traumatic Cataract

Affiliations
Comparative Study

Accuracy of Swept-Source Optical Coherence Tomography and Ultrasound Biomicroscopy for Evaluation of Posterior Lens Capsule in Traumatic Cataract

Seyed Ali Tabatabaei et al. Am J Ophthalmol. 2020 Aug.

Abstract

Purpose: To assess the efficacy of swept-source optical coherence tomography (SS-OCT) and ultrasound biomicroscopy (UBM) in detecting posterior capsule (PC) defect in patients with traumatic cataract.

Design: Observational case-series.

Methods: Sixty-seven eyes from 67 patients, with traumatic cataract severe enough to prevent slit lamp evaluation of the PC, were included in a simple sequence without randomization. Patients underwent both 50-MHz UBM and SS-OCT evaluation of the PC by different operators. Cataract surgery was then performed using a single technique.

Results: Sixty-seven eyes from 67 patients including 60 men and 7 women were studied. The mean age was 34 ± 14 years and the mean logarithm of minimal angle of resolution of visual acuity was 1.89 ± 0.71. The calculated sensitivity, specificity, and accuracy values for SS-OCT were 96.8% (95% confidence interval [CI] 83.81-99.43), 66.7% (95% CI 48.78-80.77), and 82% (95% CI 70.53-89.62), respectively. For UBM, sensitivity, specificity, and accuracy values were 82.6% (95% CI 62.86-93.02), 57.9% (95% CI 36.28-76.86), and 71.4% (95% CI 56.43-82.83), respectively. Positive predictive and negative predictive values for SS-OCT were 75% (95% CI 59.81-85.81) and 95.2% (95% CI 77.33-99.15) and for UBM were 70.4% (95% CI 51.52-84.15) and 73.3% (95% CI 48.05-89.1), respectively.

Conclusion: Although both imaging techniques are effective, SS-OCT appears to be at least comparable, or superior in special circumstances, to UBM in detecting preoperative posttraumatic PC rupture. We recommend preoperative assessment of all traumatic cataracts with SS-OCT as a part of surgical planning.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources