Abstract
Aim: To analyse the effects of different propofol starting doses as premedication for endotracheal intubation on blood pressure in neonates.
Methods: Neonates who received propofol starting doses of 1.0 mg/kg (n = 30), 1.5 mg/kg (n = 23) or 2.0 mg/kg (n = 26) as part of a previously published dose-finding study were included in this analysis. Blood pressure in the 3 dosing groups was analysed in the first 60 minutes after start of propofol.
Results: Blood pressure declined after the start of propofol in all 3 dosing groups and was not restored 60 minutes after the start of propofol. The decline in blood pressure was highest in the 2.0 mg/kg dosing group. Blood pressure decline was mainly dependent on the initial propofol starting dose rather than the cumulative propofol dose.
Conclusion: Propofol causes a dose-dependent profound and prolonged decrease in blood pressure. The use of propofol should be carefully considered. When using propofol, starting with a low dose and titrating according to sedative effect seems the safest strategy.
Keywords: blood pressure; hypotension; neonate; premedication; propofol.
© 2020 The Authors. Acta Paediatrica published by John Wiley & Sons Ltd on behalf of Foundation Acta Paediatrica.
Conflict of interest statement
All authors have no potential conflict of interest to disclose.
Figures
Comment in
-
Propofol in preterm neonates.Acta Paediatr. 2021 May;110(5):1692. doi: 10.1111/apa.15759. Epub 2021 Jan 21. Acta Paediatr. 2021. PMID: 33438289 No abstract available.
-
Reply to Letter 'Propofol in preterm neonates'.Acta Paediatr. 2021 May;110(5):1693. doi: 10.1111/apa.15755. Epub 2021 Jan 27. Acta Paediatr. 2021. PMID: 33445209 No abstract available.
Similar articles
-
Clinical evaluation of propofol as sedative for endotracheal intubation in neonates.Acta Paediatr. 2013 Nov;102(11):e487-92. doi: 10.1111/apa.12367. Epub 2013 Aug 27. Acta Paediatr. 2013. PMID: 23889264 Clinical Trial.
-
Propofol for endotracheal intubation in neonates: a dose-finding trial.Arch Dis Child Fetal Neonatal Ed. 2020 Sep;105(5):489-495. doi: 10.1136/archdischild-2019-318474. Epub 2020 Jan 13. Arch Dis Child Fetal Neonatal Ed. 2020. PMID: 31932363 Free PMC article. Clinical Trial.
-
Propofol as an induction agent for endotracheal intubation can cause significant arterial hypotension in preterm neonates.Paediatr Anaesth. 2010 Jul;20(7):605-11. doi: 10.1111/j.1460-9592.2010.03330.x. Paediatr Anaesth. 2010. PMID: 20642659
-
Propofol toxicity in critically ill pediatric patients: show us the proof.Crit Care Med. 1998 Dec;26(12):1959-60. doi: 10.1097/00003246-199812000-00019. Crit Care Med. 1998. PMID: 9875903 Review. No abstract available.
-
Hypnotic agents for induction of general anesthesia in cesarean section patients: A systematic review and meta-analysis of randomized controlled trials.J Clin Anesth. 2018 Aug;48:73-80. doi: 10.1016/j.jclinane.2018.04.010. Epub 2018 May 26. J Clin Anesth. 2018. PMID: 29778972
Cited by
-
Dose-related systemic and cerebral hemodynamic effects of norepinephrine in newborn piglets with hypoxia-reoxygenation.Pediatr Res. 2025 Apr 3. doi: 10.1038/s41390-025-04010-3. Online ahead of print. Pediatr Res. 2025. PMID: 40181145
-
Premedication before laryngoscopy in neonates: Evidence-based statement from the French society of neonatology (SFN).Front Pediatr. 2023 Jan 4;10:1075184. doi: 10.3389/fped.2022.1075184. eCollection 2022. Front Pediatr. 2023. PMID: 36683794 Free PMC article. Review.
-
Antibiotics, Analgesic Sedatives, and Antiseizure Medications Frequently Used in Critically Ill Neonates: A Narrative Review.Children (Basel). 2024 Jul 18;11(7):871. doi: 10.3390/children11070871. Children (Basel). 2024. PMID: 39062320 Free PMC article. Review.
-
Use of intravenous lidocaine for dose reduction of propofol in paediatric colonoscopy patients: a randomised placebo-controlled study.BMC Anesthesiol. 2021 Dec 1;21(1):299. doi: 10.1186/s12871-021-01525-0. BMC Anesthesiol. 2021. PMID: 34852767 Free PMC article. Clinical Trial.
References
-
- Maheshwari R, Tracy M, Badawi N, Hinder M. Neonatal endotracheal intubation: how to make it more baby friendly. J Paediatr Child Health. 2016;52(5):480‐486. - PubMed
-
- Carbajal R, Eble B, Anand KJS. Premedication for tracheal intubation in neonates: confusion or controversy? Semin Perinatol. 2007;31:309‐317. - PubMed
-
- Anand KJ, International evidence‐based group for neonatal pain . Consensus statement for the prevention and management of pain in the newborn. Arch Pediatr Adolesc Med. 2001;155:173‐180. - PubMed
-
- Kumar P, Denson SE, Mancuso TJ, Committee on Fetus and Newborn, Section on Anesthesiology and pain Medicine . Premedication for nonemergency endotracheal intubation in the neonate. Pediatrics. 2010;125(3):608‐615. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources