. 2020 Apr;15(2):63-64.
doi: 10.2185/jrm.2019-007. Epub 2020 Apr 1.

Methemoglobinemia due to local anesthesia: a rare cause of cyanosis and chest pain after placement of implantable cardioverter defibrillator

Affiliations

Methemoglobinemia due to local anesthesia: a rare cause of cyanosis and chest pain after placement of implantable cardioverter defibrillator

Yuksel Cicek et al. J Rural Med. 2020 Apr.

Abstract

Although methemoglobinemia is rare in adulthood, it may have fatal consequences if unnoticed. We planned to implant an implantable cardioverter defibrillator ICD in a 50-year-old male patient for primary prevention. Following sterile draping, prilocaine 5 mg/kg (400 mg) was injected subcutaneously for local anesthesia. We injected an additional dose of 200 mg due to pain during subclavian vein puncture. A DDD-R ICD was placed successfully within approximately 40 minutes. The patient complained of sudden chest pain and dyspnea 15 minutes after bed rest and was transferred to the coronary care unit due to cyanosis and deterioration of general status. Physical examination revealed blood pressure of 110/80 mmHg, pulse rate of 110 bpm, and otherwise unremarkable signs. Peripheral oxygen saturation was determined as 83% by pulse oximeter. Possible pneumothorax and cardiac perforation were excluded by emergency chest radiograph and echocardiography. Blood gas analyses was performed to assess for methemoglobinemia, which revealed pH 7.41, pCO2 40 mmHg, oxygen saturation 98.2%, and methemoglobin 7.9% that peaked to 12.3%. Methylene blue (1%) was slowly injected over 10 minutes at a dose of 1 mg/kg. Cyanosis waned and methemoglobin values decreased to 4.1%, 2.1%, and 1.1% at 2, 8, and 16 hours following the administration, respectively. The patient was safely discharged 2 days after implantation of pacemaker. Methemoglobinemia should be considered in cases presenting with cyanosis, non-diagnostic ECG, and a discrepancy in oxygen saturation between pulse oximetry and blood gas analyses.

Keywords: ICD; methemoglobinemia; pacemaker; prilocaine.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Cortazzo JA, Lichtman AD. Methemoglobinemia: a review and recommendations for management. J Cardiothorac Vasc Anesth 2014; 28: 1043–1047. doi: 10.1053/j.jvca.2013.02.005 - DOI - PubMed
    1. Sarı C, Aslan AN, Baştuğ S.An unusual complication after permanent pacemaker implantation: methemoglobinemia. Turk Kardiyol Dern Ars 2015; 43: 468–471. - PubMed
    1. Canpolat U, Bahadır N, Şahiner L.A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation. Turk Kardiyol Dern Ars 2017; 45: 560–562. - PubMed
    1. Svecová D, Böhmer D. [Congenital and acquired methemoglobinemia and its therapy]. Cas Lek Cesk 1998; 137: 168–170 (in Slovak). - PubMed
    1. Kreutz RW, Kinni ME. Life-threatening toxic methemoglobinemia induced by prilocaine. Oral Surg Oral Med Oral Pathol 1983; 56: 480–482. doi: 10.1016/0030-4220(83)90092-0 - DOI - PubMed