Methemoglobinemia due to local anesthesia: a rare cause of cyanosis and chest pain after placement of implantable cardioverter defibrillator
- PMID: 32256868
- PMCID: PMC7110099
- DOI: 10.2185/jrm.2019-007
Methemoglobinemia due to local anesthesia: a rare cause of cyanosis and chest pain after placement of implantable cardioverter defibrillator
Abstract
Although methemoglobinemia is rare in adulthood, it may have fatal consequences if unnoticed. We planned to implant an implantable cardioverter defibrillator ICD in a 50-year-old male patient for primary prevention. Following sterile draping, prilocaine 5 mg/kg (400 mg) was injected subcutaneously for local anesthesia. We injected an additional dose of 200 mg due to pain during subclavian vein puncture. A DDD-R ICD was placed successfully within approximately 40 minutes. The patient complained of sudden chest pain and dyspnea 15 minutes after bed rest and was transferred to the coronary care unit due to cyanosis and deterioration of general status. Physical examination revealed blood pressure of 110/80 mmHg, pulse rate of 110 bpm, and otherwise unremarkable signs. Peripheral oxygen saturation was determined as 83% by pulse oximeter. Possible pneumothorax and cardiac perforation were excluded by emergency chest radiograph and echocardiography. Blood gas analyses was performed to assess for methemoglobinemia, which revealed pH 7.41, pCO2 40 mmHg, oxygen saturation 98.2%, and methemoglobin 7.9% that peaked to 12.3%. Methylene blue (1%) was slowly injected over 10 minutes at a dose of 1 mg/kg. Cyanosis waned and methemoglobin values decreased to 4.1%, 2.1%, and 1.1% at 2, 8, and 16 hours following the administration, respectively. The patient was safely discharged 2 days after implantation of pacemaker. Methemoglobinemia should be considered in cases presenting with cyanosis, non-diagnostic ECG, and a discrepancy in oxygen saturation between pulse oximetry and blood gas analyses.
Keywords: ICD; methemoglobinemia; pacemaker; prilocaine.
©2020 The Japanese Association of Rural Medicine.
Similar articles
-
A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation.Turk Kardiyol Dern Ars. 2017 Sep;45(6):560-562. doi: 10.5543/tkda.2017.34801. Turk Kardiyol Dern Ars. 2017. PMID: 28902650
-
The Dose Makes the Poison: A Case Report of Acquired Methemoglobinemia.Int J Environ Res Public Health. 2020 Mar 12;17(6):1845. doi: 10.3390/ijerph17061845. Int J Environ Res Public Health. 2020. PMID: 32178428 Free PMC article.
-
A Case of Dapsone-induced Mild Methemoglobinemia with Dyspnea and Cyanosis.Acta Dermatovenerol Croat. 2020 Dec;28(4):249-250. Acta Dermatovenerol Croat. 2020. PMID: 33835002
-
Methemoglobinemia induced by lidocaine-prilocaine cream.Isr Med Assoc J. 2014 Apr;16(4):250-4. Isr Med Assoc J. 2014. PMID: 24834764 Review.
-
Methemoglobinemia in bronchoscopy: a case series and a review of the literature.J Bronchology Interv Pulmonol. 2013 Jul;20(3):241-6. doi: 10.1097/LBR.0b013e3182a125de. J Bronchology Interv Pulmonol. 2013. PMID: 23857198 Review.
Cited by
-
An Unexpected Complication of Pacemaker Implantation: Methemoglobinemia.Acta Cardiol Sin. 2021 Jul;37(4):449-452. doi: 10.6515/ACS.202107_37(4).20210227A. Acta Cardiol Sin. 2021. PMID: 34257497 Free PMC article. No abstract available.
-
Methaemoglobinaemia: a rare cause of chest pain, hypoxia and cyanosis.BMJ Case Rep. 2022 Mar 7;15(3):e247629. doi: 10.1136/bcr-2021-247629. BMJ Case Rep. 2022. PMID: 35256369 Free PMC article.
References
-
- Canpolat U, Bahadır N, Şahiner L.A rare cause of cyanosis and hypoxia that should not be forgotten after implantable cardioverter defibrillator implantation. Turk Kardiyol Dern Ars 2017; 45: 560–562. - PubMed
-
- Svecová D, Böhmer D. [Congenital and acquired methemoglobinemia and its therapy]. Cas Lek Cesk 1998; 137: 168–170 (in Slovak). - PubMed