Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2020 Jul;62(1):83-88.
doi: 10.1002/mus.26881. Epub 2020 Apr 27.

Cross-sectional area in median and ulnar nerve ultrasound correlates with hand volume

Affiliations
Observational Study

Cross-sectional area in median and ulnar nerve ultrasound correlates with hand volume

Melis Tahmaz et al. Muscle Nerve. 2020 Jul.

Abstract

Background: The influence of demographic and anthropometric factors on nerve cross-sectional area (CSA) reference values in high-resolution ultrasound was evaluated in a prospective observational study.

Methods: We measured CSA of median, ulnar, radial, and sural nerves in 80 healthy adults from 18 to 98 years of age. Pearson's correlation and multiple linear regression with age, gender, body mass index, and hand volume were calculated.

Results: Ulnar and median nerve CSA showed a significant positive correlation with ipsilateral hand volume. Median nerve CSA in the left forearm (mean, 6.2 mm2 ; SD, 1.2) increased by 0.006 mm2 (SE = 0.002; P < .001) per cm3 of hand volume, resulting in a difference of 1.9 mm2 predictable by hand volume (mean, 326 cm3 ; SD, 81; range, 180-500).

Conclusions: The observed correlation of CSA and hand volume may influence the interpretation of CSA values in patients with very large or small hands.

Keywords: anthropometric factors; cross-sectional area; demographic factors; hand volume; high resolution nerve ultrasound; reference values.

PubMed Disclaimer

References

REFERENCES

    1. Cartwright MS, Passmore LV, Yoon JS, Brown ME, Caress JB, Walker FO. Cross-sectional area reference values for nerve ultrasonography. Muscle Nerve. 2008;37:566-571.
    1. Kerasnoudis A, Pitarokoili K, Behrendt V, Gold R, Yoon MS. Cross sectional area reference values for sonography of peripheral nerves and brachial plexus. Clin Neurophysiol. 2013;124:1881-1888.
    1. Won SJ, Kim BJ, Park KS, Yoon JS, Choi H. Reference values for nerve ultrasonography in the upper extremity. Muscle Nerve. 2013;47:864-871.
    1. Marciniak C, Caldera F, Welty L, et al. High-resolution median nerve sonographic measurements: correlations with median nerve conduction studies in healthy adults. J Ultrasound Med. 2013;32:2091-2098.
    1. Kessler JM, de la Lama M, Umans HR, Negron J. High-frequency sonography of the volar digital nerves of the hand. Muscle Nerve. 2012;45:222-226.

Publication types

LinkOut - more resources