Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Feb 1;35(1):34-40.
doi: 10.21470/1678-9741-2019-0147.

Influence of Bentall Procedure on Left Ventricular Function

Affiliations

Influence of Bentall Procedure on Left Ventricular Function

Serkan Burç Deşer et al. Braz J Cardiovasc Surg. .

Abstract

Objective: To evaluate the influence of Bentall procedure on left ventricular function and condition on long-term follow-up.

Methods: Seventy-three consecutive patients who underwent an aortic root and ascending aorta replacement with composite valve button Bentall or flanged Bentall technique, from January 2007 to November 2018, were included in this retrospective study.

Results: Postoperative left ventricular ejection fraction significantly increased (52.14±11.38 vs. 56.79±11.36; P=0.041), left ventricular end-systolic diameter significantly reduced (38.25±9.31 mm vs. 34.17±9.15 mm; P=0.027), left ventricular end-diastolic diameter significantly reduced (56.42±9.72 mm vs. 51.58±9.03 mm; P=0.01), and left atrial diameter significantly reduced (45.33±12.77 mm vs. 39.25±12.41 mm; P=0.01), compared to preoperative values. Our long-term survival results are comparable with previous studies in which survival rates in 5 years and 10 years were 83.5% and 69.8%, respectively. In comparing patients according to their New York Heart Association (NYHA) functional class, it was shown that their postoperative functional capacity was improved during the follow-up period (2.1±0.56 vs. 1.2±0.42; P=0.001).

Conclusion: The Bentall procedure significantly improved the left ventricular systolic function and condition and decreased the left ventricular end-systolic and end-diastolic diameters and the left atrial diameter on long-term follow-up, based on the transthoracic echocardiography. Bentall procedure can be performed with acceptable mortality and morbidity rates on long-term follow-up.

Keywords: Aorta; Aortic Valce; Atrial Fibrilation; Diastole; Echocardiography; Left; Survival Rate; Ventricular Function.

PubMed Disclaimer

Conflict of interest statement

No conflict of interest.

Figures

Fig. 1
Fig. 1
Depiction of button Bentall (A) and flanged Bentall (B) procedures.
Fig. 2
Fig. 2
Cumulative survival rate of patients.

References

    1. Dhurandhar V, Parikh R, Saxena A, Vallely MP, Wilson MK, Black DA, et al. The aortic root replacement procedure: 12-year experience from the Australian and New Zealand society of cardiac and thoracic surgeons database. Heart Lung Circ. 2016;25(12):1245–1251. doi: 10.1016/j.hlc.2016.04.014. - DOI - PubMed
    1. Nataf P, Lansac E. Dilation of the thoracic aorta: medical and surgical management. Heart. 2006;92(9):1345–1352. doi: 10.1136/hrt.2005.074781. - DOI - PMC - PubMed
    1. Bentall H, De Bono A. A technique for complete replacement of the ascending aorta. Thorax. 1968;23(4):338–339. doi: 10.1136/thx.23.4.338. - DOI - PMC - PubMed
    1. Kouchoukos NT, Wareing TH, Murphy SF, Perrillo JB. Sixteen-year experience with aortic root replacement. Results of 172 operations. Ann Surg. 1991;214(3):308–320. doi: 10.1097/00000658-199109000-00013. - DOI - PMC - PubMed
    1. David TE. Aortic valve sparing operations: outcomes at 20 years. Ann Cardiothorac Surg. 2013;2(1):24–29. doi: 10.3978/j.issn.2225-319X.2012.11.15. - DOI - PMC - PubMed

LinkOut - more resources