Is Central Corneal Thickness a reliable independent factor in decision-making regarding the management of patients with high IOP?
- PMID: 32292854
- PMCID: PMC7141911
Is Central Corneal Thickness a reliable independent factor in decision-making regarding the management of patients with high IOP?
Abstract
As time passes, we discover that things that were supposedly considered to be well known are in fact not as they seemed. Maybe the process is like this because we try to simplify our daily practice, but by doing so, don't we tend to trespass the whole picture? However, what happens if these factors affect our decision-making? Clinicians should incorporate CCT into the thinking process and should not focus on "corrected IOPs", because, besides CCT, there are many factors of corneal biomechanics that affect IOP.
Keywords: Central Corneal Thickness; GAT IOP; adjusted IOP.
©Romanian Society of Ophthalmology.
Similar articles
-
Relationship between corneal biomechanical properties, central corneal thickness, and intraocular pressure across the spectrum of glaucoma.Am J Ophthalmol. 2012 May;153(5):840-849.e2. doi: 10.1016/j.ajo.2011.10.032. Epub 2012 Feb 4. Am J Ophthalmol. 2012. PMID: 22310080
-
Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls.Br J Ophthalmol. 2020 Jan;104(1):121-126. doi: 10.1136/bjophthalmol-2018-313493. Epub 2019 Mar 28. Br J Ophthalmol. 2020. PMID: 30923134 Free PMC article.
-
Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer.Invest Ophthalmol Vis Sci. 2006 Dec;47(12):5337-47. doi: 10.1167/iovs.06-0557. Invest Ophthalmol Vis Sci. 2006. PMID: 17122122
-
Incorporating corneal pachymetry into the management of glaucoma.J Cataract Refract Surg. 2009 Sep;35(9):1623-8. doi: 10.1016/j.jcrs.2009.05.015. J Cataract Refract Surg. 2009. PMID: 19683164 Review.
-
Central corneal thickness, tonometry, and glaucoma risk--a guide for the perplexed.Can J Ophthalmol. 2007 Aug;42(4):562-6. Can J Ophthalmol. 2007. PMID: 17641698 Review.
Cited by
-
Evaluating the Effect of Topical Atropine Use for Myopia Control on Intraocular Pressure by Using Machine Learning.J Clin Med. 2020 Dec 30;10(1):111. doi: 10.3390/jcm10010111. J Clin Med. 2020. PMID: 33396943 Free PMC article.
References
-
- Goldmann Tonometer Remains Gold Standard for Measuring IOP. AAO 2018 Daily/ aao.org
-
- Clinical Measurement of Intraocular Pressure Basic and Clinical Science Course – Excerpt aao
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials