Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2020 May;13(5):e008161.
doi: 10.1161/CIRCEP.119.008161. Epub 2020 Apr 17.

Heterogeneity in Conduction Underlies Obesity-Related Atrial Fibrillation Vulnerability

Affiliations
Observational Study

Heterogeneity in Conduction Underlies Obesity-Related Atrial Fibrillation Vulnerability

Corina Schram-Serban et al. Circ Arrhythm Electrophysiol. 2020 May.

Abstract

Background: Obese patients are more vulnerable to development of atrial fibrillation but pathophysiology underlying this relation is only partly understood. The aim of this study is to compare the severity and extensiveness of conduction disorders between obese patients and nonobese patients measured at a high-resolution scale.

Methods: Patients (N=212) undergoing cardiac surgery (male:161, 63±11 years) underwent epicardial mapping of the right atrium, Bachmann bundle, and left atrium during sinus rhythm. Conduction delay (CD) was defined as interelectrode conduction time of 7 to 11 ms and conduction block (CB) as conduction time ≥12 ms. Prevalence of CD/CB, continuous CDCB (cCDCB), length of CD/CB/cCDCB lines, and severity of CB were analyzed.

Results: In obese patients, the overall incidence of CD (3.1% versus 2.6%; P=0.002), CB (1.8% versus 1.2%; P<0.001), and cCDCB (2.6% versus 1.9%; P<0.001) was higher and CD (P=0.012) and cCDCB (P<0.001) lines are longer. There were more conduction disorders at Bachmann bundle and this area has a higher incidence of CD (4.4% versus 3.3%, P=0.002), CB (3.1% versus 1.6%, P<0.001), cCDCB (4.6% versus 2.7%, P<0.001) and longer CD (P<0.001) or cCDCB (P=0.017) lines. The severity of CB is also higher, particularly in the Bachmann bundle (P=0.008) and pulmonary vein (P=0.020) areas. In addition, obese patients have a higher incidence of early de-novo postoperative atrial fibrillation (P=0.003). Body mass index (P=0.037) and the overall amount of CB (P=0.012) were independent predictors for incidence of early postoperative atrial fibrillation.

Conclusions: Compared with nonobese patients, obese patients have higher incidences of conduction disorders, which are also more extensive and more severe. These differences in heterogeneity in conduction are already present during sinus rhythm and may explain the higher vulnerability to atrial fibrillation of obese patients.

Keywords: atrial fibrillation; body mass index; cardiac electrophysiology; incidence; obesity.