. 2020 Jul:134:110042.
doi: 10.1016/j.ijporl.2020.110042. Epub 2020 Apr 8.

Pediatric airway surgery under spontaneous respiration using high-flow nasal oxygen

Affiliations

Pediatric airway surgery under spontaneous respiration using high-flow nasal oxygen

Jeong-Yeon Ji et al. Int J Pediatr Otorhinolaryngol. 2020 Jul.

Abstract

Objectives: In pediatric airway surgery, SponTaneous Respiration using IntraVEnous anesthesia and Hi-flow nasal oxygen (STRIVE Hi) has not been well explored. Here, we report our experience of using STRIVE Hi in endoscopic evaluations and surgeries of the pediatric airway.

Methods: This retrospective review was based on 45 airway procedures conducted under STRIVE Hi, performed by a single surgeon at a single institute from May 2017 to September 2018. After induction of anesthesia, continuous infusion with propofol and remifentanil was provided to ensure an adequate level of anesthesia and supply of humidified oxygen via a nasal cannula. Monitoring was conducted using a transcutaneous CO2 sensor and a pulse oximeter, and the oxygen reserve and bispectral indexes were measured. No muscle relaxant was administered.

Results: The median age of the patients was 16.0 months (range: 1-215 months) and the median weight was 10.2 kg (range: 2.4-38.5 kg). The median duration of spontaneous respiration was min 40 (range: 10-140 min). The airway procedures included diagnostic microlaryngoscopy, tracheocutaneous fistula excision, balloon dilation, supraglottoplasty, laryngeal cleft repair, injection laryngoplasty, papilloma excision, and subglottic cyst removal. During these procedures, STRIVE Hi facilitated evaluation of dynamic obstruction of the airway and the immediate outcome of surgical treatment and provided a good surgical view. Intubation and the termination of spontaneous respiration were required in only five patients.

Conclusions: STRIVE Hi is an effective and feasible anesthesia option in pediatric airway surgery. It provides unobstructed surgical access and is applicable to a wide range of procedures.

Keywords: High-flow nasal oxygen; Pediatric airway surgery; Pediatric anesthesia; Spontaneous respiration.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that there is no conflict of interests regarding the publication of this article.

MeSH terms

LinkOut - more resources