Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2020 May 11;13(9):1071-1082.
doi: 10.1016/j.jcin.2019.12.026. Epub 2020 Apr 15.

5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial

Affiliations
Free article
Randomized Controlled Trial

5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial

Mohamed Abdel-Wahab et al. JACC Cardiovasc Interv. .
Free article

Abstract

Objectives: The purpose of this study was to evaluate clinical and echocardiographic outcome data of the CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients with Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT) trial at 5 years.

Background: The CHOICE trial was designed to compare device performance of a balloon-expandable (BE) transcatheter heart valve (THV) versus a self-expanding (SE) THV.

Methods: The CHOICE trial is an investigator-initiated trial that randomized 241 high-risk patients with severe symptomatic aortic stenosis and an anatomy suitable for treatment with both BE and SE THVs to transfemoral transcatheter aortic valve replacement with either device. The primary endpoint was device success. Patients were followed up to 5 years, with assessment of clinical outcomes, and echocardiographic evaluation of valve function and THV durability.

Results: After 5 years, there were no statistically significant differences between BE and SE valves in the cumulative incidence of death from any cause (53.4% vs. 47.6%; p = 0.38), death from cardiovascular causes (31.6% vs. 21.5%; p = 0.12), all strokes (17.5% vs. 16.5%; p = 0.73), and repeat hospitalization for heart failure (28.9% vs. 22.5%; p = 0.75). SE patients had larger prosthetic valve area (1.6 ± 0.5 cm2 vs. 1.9 ± 0.5 cm2; p = 0.02) with a lower mean transprosthetic gradient (12.2 ± 8.7 mm Hg vs. 6.9 ± 2.7 mm Hg; p = 0.001) at 5 years. No differences were observed in the rates of paravalvular regurgitation. Clinical valve thrombosis occurred in 7 BE patients (7.3%) and 1 SE patient (0.8%; p = 0.06), and moderate or severe structural valve deterioration in 6 BE patients (6.6%) and no SE patient (0%; p = 0.018). The rate of bioprosthetic valve failure was low and not significantly different between both groups (4.1% vs. 3.4%; p = 0.63).

Conclusions: Five-year follow-up of patients in the CHOICE trial revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with early-generation BE and SE valves that were not statistically significantly different, with limited statistical power. Forward flow hemodynamics were significantly better with the SE valve. Moderate or severe structural valve deterioration was uncommon but occurred more frequently with the BE valve. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial [CHOICE]; NCT01645202).

Keywords: TAVR; aortic stenosis; balloon-expandable; durability; self-expanding.

PubMed Disclaimer

Comment in

  • Transcatheter Heart Valves: Not a Matter of Chance But of CHOICE.
    Esposito G, Franzone A. Esposito G, et al. JACC Cardiovasc Interv. 2020 May 11;13(9):1083-1085. doi: 10.1016/j.jcin.2020.01.236. Epub 2020 Apr 15. JACC Cardiovasc Interv. 2020. PMID: 32305391 No abstract available.
  • The CHOICE Randomized Clinical Trial.
    Bisson A, Fauchier L, Collart F, Cuisset T, Deharo P. Bisson A, et al. JACC Cardiovasc Interv. 2020 Jul 13;13(13):1609-1610. doi: 10.1016/j.jcin.2020.04.049. JACC Cardiovasc Interv. 2020. PMID: 32646707 No abstract available.
  • Reply: The CHOICE Randomized Clinical Trial.
    Abdel-Wahab M, Kitamura M, Richardt G. Abdel-Wahab M, et al. JACC Cardiovasc Interv. 2020 Jul 13;13(13):1610-1611. doi: 10.1016/j.jcin.2020.05.044. JACC Cardiovasc Interv. 2020. PMID: 32646709 No abstract available.

Publication types

MeSH terms

Associated data

LinkOut - more resources