Single-center experience with partial support device in destination therapy for end-stage heart failure
- PMID: 32324900
- DOI: 10.1111/aor.13714
Single-center experience with partial support device in destination therapy for end-stage heart failure
Abstract
Ventricular assist devices (VADs) are considered the standard of care for end-stage heart failure (HF) patients. Despite increasing confidence in the technology, evidence data, endorsement by scientific societies and guidelines, the number of implants reached a steady state and is not increasing at the expected pace. This is most likely related to complications that are still burdening the technology and consequently excluding the most needy, ill, and fragile population. In this manuscript we are reporting a single-center experience in a very fragile, elderly and end-stage HF population, with a superficial, partial support device: the CircuLite Synergy. The patients were included in the pre-CE mark clinical study and consequently the device underwent technical adjustment during the support, based on the complications recorded. At our institution were implanted 6 patients overall: 3 patients survived to discharge and 2 survived up to 5 years. Most of the complications recorded were due to patients' frailty and overall clinical conditions. The initial experience with the CircuLite Synergy device is proving that a more "superficial" device might be more tolerable in an elderly, frail population. Partial support has proven hemodynamically efficacious and efficient in relieving heart failure symptoms, improving medical therapy tolerability, and improving quality of life. Unfortunately, the technology was not made available due to financial uncertainty and poor management, but we hope that once the concept has been proved someone will collect the legacy.
Keywords: destination therapy; left ventricular assist device; partial support.
© 2020 International Center for Artificial Organ and Transplantation (ICAOT) and Wiley Periodicals LLC.
References
REFERENCES
-
- Kormos RL, Cowger J, Pagani FD, Teuteberg JJ, Goldstein DJ, Jacobs JP, et al. The Society of Thoracic Surgeons Intermacs Database annual report: evolving indications, outcomes, and scientific partnerships. Ann Thorac Sur. 2019;107:341-53.
-
- Estep JD, Starling RC, Horstmanshof DA, Milano CA, Selzman CH, Shah KB, et al. Risk assessment and comparative effectiveness of left ventricular assist device and medical management in ambulatory heart failure patients: results from the ROADMAP study. J Am Coll Cardiol. 2015;66:1747-61.
-
- Morley D, Litwak K, Ferber P, Spence P, Dowling R, Meyns B, et al. Hemodynamic effects of partial ventricular support in chronic heart failure: results of simulation validated with in vivo data. J Thorac Cardiovasc Surg. 2007;133:21-8.
-
- Meyns B, Klotz S, Simon A, Droogne W, Rega F, Griffith B, et al. Proof of concept: hemodynamic response to long-term partial ventricular support with the synergy pocket micro-pump. J Am Coll Cardiol. 2009;54:79-86.
-
- Meyns B, Rega F, Barbone A, Ornaghi D, Strueber M, Simon A, et al. CIRCULITE® SYNERGY® system for the treatment of intermacs ≥4 heart failure. J Heart Lung Transplant. 2013;32:S148.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous